***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics XQEHLANDE (Material Number: XQEHLANDE) is a sophisticated valve assembly designed for efficient accumulator charging using a fixed displacement pump. This assembly automatically unloads the pump when pressure reaches a pre-set level and reactivates it once the pressure drops to a specified value, ensuring optimal system performance. It features a ventable relief that serves both as an unloading mechanism for the pump and as an overpressure relief system. The valve assembly includes additional functionalities such as a circuit to soften pump unloading and options for remote sensing of accumulator pressure, enhancing its adaptability in various applications. For effective operation, it requires a separate drain line to mitigate erratic performance due to tank line pressure fluctuations. Users must carefully select the adjustment range since low operating pressures and small differentials can lead to narrow bands between unload and reset, necessitating precise system design. High flow rates can cause significant pressure drops, affecting the differential available for the valve's operation. The assembly\u2019s large porting encourages the use of substantial piping to minimize issues related to flow-induced pressure drops. The pilot valve's spool design maintains a consistent differential ratio due to its durable construction that resists wear over time. It is crucial that the accumulator pilot valve is set below any reliefs on the pump side to prevent excessive heating. The included relief acts as an overpressure device, set above the highest setting of the pilot valve and capped for safety. This line-mount body type assembly has a capacity of 20 gpm (80 L/min) with mounting hole specifications designed for ease of installation. The use of remote sensing is recommended to minimize errors on the accumulator side, ensuring precise control over system operations.

This valve assembly is meant to charge an accumulator using a fixed displacement pump. When the pressure reaches the set point of the valve, the pump is unloaded. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the pump is brought back on line to recharge the accumulator. The ventable relief serves a dual purpose as a main stage to unload the pump and as a system over-pressure relief. The assembly has two additional features; a simple circuit that softens the unloading of the pump and provisions for remote sensing of the accumulator pressure.

  • When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
  • NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
  • The pressure setting and the resultant reseat pressure are in reference to the port 1 area of the QPA* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow. Use of the remote sense for accumulator pressure will minimize the error on the accumulator side of the circuit. Use of the remote sense is highly recommended.
  • The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
  • The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
  • The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
  • The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.

Capacity20 gpm80 L/min.
Body TypeLine mountLine mount
Mounting Hole Diameter.41 in.10,4 mm
Mounting Hole DepthThroughThrough
Mounting Hole Quantity22

Show FAQ

Additional Resources



Notes:
  • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.