***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics XQEHLANCW (XQEHLANCW) is a sophisticated valve assembly designed to efficiently charge an accumulator using a fixed displacement pump. This assembly is engineered to automatically unload the pump when the system pressure reaches a predetermined set point, and re-engage it when the pressure drops to a specific value dictated by the pilot valve's fixed percentage. The ventable relief feature serves dual roles: acting as the main stage for unloading the pump and functioning as an overpressure relief for the system. Additional features include a circuit that softens pump unloading and provisions for remote sensing of accumulator pressure, allowing for precise monitoring and control. For optimal performance, it is crucial to implement a separate drain line to mitigate erratic operations caused by fluctuations in tank line pressure. Special attention should be given to selecting an appropriate adjustment range, considering that system pressure drops and flow rates can significantly impact valve operation. Low operating pressures combined with low differentials create narrow bands between unload and reset points, necessitating careful system design. High flow rates typically result in high pressure drops, which can reduce the differential available for valve operation. The assembly features large porting relative to its capacity, encouraging the use of large piping to minimize issues related to flow-induced pressure drop. The spool design ensures a consistent differential ratio over time due to its wear-resistant construction. It is essential that the accumulator pilot valve be set below any reliefs on the pump side of the system to prevent potential overheating issues. The relief mechanism within this package acts as an overpressure device, preset higher than any pilot valve setting and securely capped for safety.

This valve assembly is meant to charge an accumulator using a fixed displacement pump. When the pressure reaches the set point of the valve, the pump is unloaded. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the pump is brought back on line to recharge the accumulator. The ventable relief serves a dual purpose as a main stage to unload the pump and as a system over-pressure relief. The assembly has two additional features; a simple circuit that softens the unloading of the pump and provisions for remote sensing of the accumulator pressure.

  • When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
  • NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
  • The pressure setting and the resultant reseat pressure are in reference to the port 1 area of the QPA* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow. Use of the remote sense for accumulator pressure will minimize the error on the accumulator side of the circuit. Use of the remote sense is highly recommended.
  • The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
  • The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
  • The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
  • The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.

Capacity20 gpm80 L/min.
Body TypeLine mountLine mount
Mounting Hole Diameter.41 in.10,4 mm
Mounting Hole DepthThroughThrough
Mounting Hole Quantity22

Show FAQ

Additional Resources



Notes:
  • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.