***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics XQEHLANBX (Material Number: XQEHLANBX) is a versatile valve assembly designed for charging an accumulator with a fixed displacement pump. When the system reaches a specific pressure set point, the valve unloads the pump, and once the pressure drops to a predetermined level, it reactivates the pump to recharge the accumulator. This assembly features a ventable relief that functions both as a main stage for unloading and as an overpressure relief mechanism. It includes additional features such as softening circuits for smooth pump unloading and provisions for remote sensing of accumulator pressure. For optimal performance, it's crucial to use a separate drain line to avoid erratic operation due to tank line pressure fluctuations. Selecting an appropriate adjustment range is essential, as low operating pressures and differentials can lead to narrow bands between unload and reset points, necessitating precise system design. High flow rates may result in significant pressure drops, affecting the valve's differential operation. The assembly's large porting encourages using large piping to minimize flow-induced pressure drops. The spool design of the pilot valve ensures consistent differential ratios due to non-wearing diameters on the spool. The accumulator pilot valve must be set below any reliefs on the pump side of the system to avoid excessive heating. The overpressure relief in this package is intended as a safety device, set higher than the pilot valve's maximum setting and capped accordingly. With a capacity of 20 gpm (80 L/min), this line-mounted assembly requires careful consideration of maximum system pressures, particularly when using aluminum manifolds not rated above 3000 psi (210 bar).
The Sun Hydraulics XQEHLANBX (Material Number: XQEHLANBX) is a versatile valve assembly designed for charging an accumulator with a fixed displacement pump. When the system reaches a specific pressure set point, the valve unloads the pump, and once the pressure drops to a predetermined level, it reactivates the pump to recharge the accumulator. This assembly features a ventable relief that functions both as a main stage for unloading and as an overpressure relief mechanism. It includes additional features such as softening circuits for smooth pump unloading and provisions for remote sensing of accumulator pressure. For optimal performance, it's crucial to use a separate drain line to avoid erratic operation due to tank line pressure fluctuations. Selecting an appropriate adjustment range is essential, as low operating pressures and differentials can lead to narrow bands between unload and reset points, necessitating precise system design. High flow rates may result in significant pressure drops, affecting the valve's differential operation. The assembly's large porting encourages using large piping to minimize flow-induced pressure drops. The spool design of the pilot valve ensures consistent differential ratios due to non-wearing diameters on the spool. The accumulator pilot valve must be set below any reliefs on the pump side of the system to avoid excessive heating. The overpressure relief in this package is intended as a safety device, set higher than the pilot valve's maximum setting and capped accordingly. With a capacity of 20 gpm (80 L/min), this line-mounted assembly requires careful consideration of maximum system pressures, particularly when using aluminum manifolds not rated above 3000 psi (210 bar).
This valve assembly is meant to charge an accumulator using a fixed displacement pump. When the pressure reaches the set point of the valve, the pump is unloaded. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the pump is brought back on line to recharge the accumulator. The ventable relief serves a dual purpose as a main stage to unload the pump and as a system over-pressure relief. The assembly has two additional features; a simple circuit that softens the unloading of the pump and provisions for remote sensing of the accumulator pressure.
- When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
- NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
- The pressure setting and the resultant reseat pressure are in reference to the port 1 area of the QPA* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow. Use of the remote sense for accumulator pressure will minimize the error on the accumulator side of the circuit. Use of the remote sense is highly recommended.
- The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
- The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
- The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
- The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.
| Capacity | 20 gpm80 L/min. |
| Body Type | Line mountLine mount |
| Mounting Hole Diameter | .41 in.10,4 mm |
| Mounting Hole Depth | ThroughThrough |
| Mounting Hole Quantity | 22 |
Show FAQ
Additional Resources
- Integrated Packages: Solutions That Grow Your Reputation
- Fluid and Temperature Recommendations
- Sun's Floating Style Screw-In Cartridge
- Sun Model Code Explanation; 999-901-334
- Custom Integrated Packages from Sun
Notes:
- Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.