You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
XQEHLANBW


$1,013.30 USD

Tags:

  • SUN HYDRAULICS
  • Material:XQEHLANBW
  • Model:XQEH-LAN-BW
  • Summary:Y-assembly

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics XQEHLANBW (Material Number: XQEHLANBW) is a sophisticated valve assembly designed for efficiently charging an accumulator using a fixed displacement pump. This assembly automatically unloads the pump when the pressure reaches a predetermined set point and re-engages it when the pressure drops to a specified level, ensuring consistent system performance. It features a ventable relief that serves dual purposes: unloading the pump and acting as an overpressure relief for the system. Notably, this assembly includes mechanisms for softening the pump's unloading process and allows remote sensing of accumulator pressure, enhancing operational precision. For optimal performance, it is crucial to incorporate a separate drain line to prevent erratic operations due to tank line pressure fluctuations. The system's design must carefully consider adjustment ranges, as low operating pressures and differentials require precise calibration. The valve's design minimizes errors in accumulator pressure readings by utilizing remote sensing capabilities. The assembly is engineered with large porting relative to its capacity, encouraging the use of large piping to mitigate flow-induced pressure drops. Its pilot valve spool design maintains a fixed differential ratio, ensuring long-term reliability without wear-induced changes. Additionally, setting the accumulator pilot valve below any system reliefs on the pump side is essential to avoid excessive heating. The included relief mechanism functions as an overpressure device set higher than the pilot valve's maximum setting and is capped for security. With a capacity of 20 gpm (80 L/min), this line-mount body type assembly requires specific mounting hole dimensions (0.41 in./10.4 mm diameter) with two holes through its structure for secure installation.

This valve assembly is meant to charge an accumulator using a fixed displacement pump. When the pressure reaches the set point of the valve, the pump is unloaded. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the pump is brought back on line to recharge the accumulator. The ventable relief serves a dual purpose as a main stage to unload the pump and as a system over-pressure relief. The assembly has two additional features; a simple circuit that softens the unloading of the pump and provisions for remote sensing of the accumulator pressure.

  • When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
  • NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
  • The pressure setting and the resultant reseat pressure are in reference to the port 1 area of the QPA* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow. Use of the remote sense for accumulator pressure will minimize the error on the accumulator side of the circuit. Use of the remote sense is highly recommended.
  • The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
  • The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
  • The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
  • The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.

Capacity20 gpm80 L/min.
Body TypeLine mountLine mount
Mounting Hole Diameter.41 in.10,4 mm
Mounting Hole DepthThroughThrough
Mounting Hole Quantity22

Show FAQ

Additional Resources



Notes:
  • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.