***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics XQEHLANAE (XQEHLANAE) is a sophisticated valve assembly designed for charging accumulators with the aid of a fixed displacement pump. This assembly efficiently manages the pump's operation by unloading it when the pressure reaches a predetermined set point and re-engaging it when the pressure falls to a specific level determined by the pilot valve. The ventable relief serves dual functions: unloading the pump and acting as an overpressure relief for the system. Additionally, this assembly includes features that ease the unloading process and allow for remote sensing of accumulator pressure, enhancing its operational efficiency. A separate drain line is necessary to avoid erratic behavior due to tank line pressure fluctuations. It's crucial to select an appropriate adjustment range considering system pressure drops and flow rates, as these factors influence the functionality of unloading valves. The assembly's design ensures minimal error in accumulator pressure through remote sensing, which is strongly recommended for optimal performance. The porting on this valve assembly is intentionally large relative to its capacity, encouraging users to employ large piping and minimize flow-induced pressure drops. The spool design in the pilot valve maintains a consistent differential ratio, ensuring reliable performance over time without wear-related changes. Setting the accumulator pilot valve below any pump-side reliefs is essential to prevent excessive heating. This package incorporates a relief mechanism intended solely as an overpressure device, set higher than any pilot valve settings and securely capped. With a capacity of 20 gpm (80 L/min), this line mount body type requires two mounting holes with specific dimensions for installation.

This valve assembly is meant to charge an accumulator using a fixed displacement pump. When the pressure reaches the set point of the valve, the pump is unloaded. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the pump is brought back on line to recharge the accumulator. The ventable relief serves a dual purpose as a main stage to unload the pump and as a system over-pressure relief. The assembly has two additional features; a simple circuit that softens the unloading of the pump and provisions for remote sensing of the accumulator pressure.

  • When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
  • NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
  • The pressure setting and the resultant reseat pressure are in reference to the port 1 area of the QPA* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow. Use of the remote sense for accumulator pressure will minimize the error on the accumulator side of the circuit. Use of the remote sense is highly recommended.
  • The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
  • The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
  • The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
  • The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.

Capacity20 gpm80 L/min.
Body TypeLine mountLine mount
Mounting Hole Diameter.41 in.10,4 mm
Mounting Hole DepthThroughThrough
Mounting Hole Quantity22

Show FAQ

Additional Resources



Notes:
  • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.