***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics XQEGLANEX (XQEGLANEX) is a specialized valve assembly designed to efficiently charge an accumulator using a fixed displacement pump. This assembly operates by unloading the pump once the pressure reaches a predetermined set point, and re-engaging it when the pressure falls below a specific threshold, as determined by the pilot valve's fixed percentage. The ventable relief feature serves dual functions: it acts as a main stage for unloading the pump and as an overpressure relief for the system. Key features include a circuit that softens pump unloading and provisions for remote sensing of accumulator pressure, which helps minimize errors on the accumulator side. For optimal performance, this assembly requires a separate drain line to prevent operational inconsistencies caused by tank line pressure fluctuations. It's crucial to select an appropriate adjustment range, considering that system pressure drops and flow rates can impact unloading valve operations. The assembly is designed with large porting relative to its capacity to encourage using large piping, minimizing flow-induced pressure drops. The spool design of the pilot valve maintains a consistent differential ratio due to its non-wearing design. It's important that the accumulator pilot valve is set below any relief valves in the pump side of the system to avoid excessive heating. The included relief valve acts as an overpressure device and is set higher than the highest setting of the pilot valve. The XQEGLANEX has a capacity of 20 gpm (80 L/min), with specific mounting requirements including 22 through holes with a diameter of .41 inches (10.4 mm). This line-mounted body type ensures robust performance in hydraulic systems requiring precise control over accumulator charging processes.

This valve assembly is meant to charge an accumulator using a fixed displacement pump. When the pressure reaches the set point of the valve, the pump is unloaded. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the pump is brought back on line to recharge the accumulator. The ventable relief serves a dual purpose as a main stage to unload the pump and as a system over-pressure relief. The assembly has two additional features; a simple circuit that softens the unloading of the pump and provisions for remote sensing of the accumulator pressure.

  • When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
  • NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
  • The pressure setting and the resultant reseat pressure are in reference to the port 1 area of the QPA* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow. Use of the remote sense for accumulator pressure will minimize the error on the accumulator side of the circuit. Use of the remote sense is highly recommended.
  • The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
  • The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
  • The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
  • The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.

Capacity20 gpm80 L/min.
Check Cracking Pressure50 psi3,5 bar
Body TypeLine mountLine mount
Mounting Hole Diameter.41 in.10,4 mm
Mounting Hole DepthThroughThrough
Mounting Hole Quantity22

Show FAQ

Additional Resources



Notes:
  • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.