***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics XQEGLANEW (XQEGLANEW) is a sophisticated valve assembly designed specifically for charging accumulators using a fixed displacement pump. This assembly operates by unloading the pump when the system pressure reaches a predetermined set point, and re-engaging it when pressure drops to a level defined by the pilot valve's fixed percentage. It features a ventable relief that acts both as an overpressure relief and as a main stage to unload the pump. The assembly includes mechanisms to soften the pump's unloading process and allows for remote sensing of accumulator pressure, enhancing precision in system operations. To ensure optimal performance, it is crucial to implement a separate drain line to avoid erratic operation due to tank line pressure fluctuations. Selecting an appropriate adjustment range is vital since system pressure drops and flows can influence unloading valve operations. Low operating pressures with narrow differentials necessitate precise design, while high flow rates could lead to significant pressure drops, impacting differential performance. The assembly's porting is intentionally large relative to its capacity, promoting the use of larger piping to mitigate flow-induced pressure drop issues. The spool design within the pilot valve maintains a fixed differential ratio through diameters on the spool that resist wear over time. It's important that the accumulator pilot valve settings are below any reliefs on the pump side of the system to prevent excessive heating. The integrated relief serves as an overpressure safeguard, preset higher than any pilot valve setting and sealed for protection. This line mount body type supports up to 20 gpm (80 L/min) with a check cracking pressure of 50 psi (3.5 bar). The mounting requires 22 holes with specific diameter and depth specifications for secure installation.
The Sun Hydraulics XQEGLANEW (XQEGLANEW) is a sophisticated valve assembly designed specifically for charging accumulators using a fixed displacement pump. This assembly operates by unloading the pump when the system pressure reaches a predetermined set point, and re-engaging it when pressure drops to a level defined by the pilot valve's fixed percentage. It features a ventable relief that acts both as an overpressure relief and as a main stage to unload the pump. The assembly includes mechanisms to soften the pump's unloading process and allows for remote sensing of accumulator pressure, enhancing precision in system operations. To ensure optimal performance, it is crucial to implement a separate drain line to avoid erratic operation due to tank line pressure fluctuations. Selecting an appropriate adjustment range is vital since system pressure drops and flows can influence unloading valve operations. Low operating pressures with narrow differentials necessitate precise design, while high flow rates could lead to significant pressure drops, impacting differential performance. The assembly's porting is intentionally large relative to its capacity, promoting the use of larger piping to mitigate flow-induced pressure drop issues. The spool design within the pilot valve maintains a fixed differential ratio through diameters on the spool that resist wear over time. It's important that the accumulator pilot valve settings are below any reliefs on the pump side of the system to prevent excessive heating. The integrated relief serves as an overpressure safeguard, preset higher than any pilot valve setting and sealed for protection. This line mount body type supports up to 20 gpm (80 L/min) with a check cracking pressure of 50 psi (3.5 bar). The mounting requires 22 holes with specific diameter and depth specifications for secure installation.
This valve assembly is meant to charge an accumulator using a fixed displacement pump. When the pressure reaches the set point of the valve, the pump is unloaded. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the pump is brought back on line to recharge the accumulator. The ventable relief serves a dual purpose as a main stage to unload the pump and as a system over-pressure relief. The assembly has two additional features; a simple circuit that softens the unloading of the pump and provisions for remote sensing of the accumulator pressure.
- When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
- NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
- The pressure setting and the resultant reseat pressure are in reference to the port 1 area of the QPA* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow. Use of the remote sense for accumulator pressure will minimize the error on the accumulator side of the circuit. Use of the remote sense is highly recommended.
- The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
- The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
- The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
- The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.
| Capacity | 20 gpm80 L/min. |
| Check Cracking Pressure | 50 psi3,5 bar |
| Body Type | Line mountLine mount |
| Mounting Hole Diameter | .41 in.10,4 mm |
| Mounting Hole Depth | ThroughThrough |
| Mounting Hole Quantity | 22 |
Show FAQ
Additional Resources
- Integrated Packages: Solutions That Grow Your Reputation
- Fluid and Temperature Recommendations
- Sun's Floating Style Screw-In Cartridge
- Sun Model Code Explanation; 999-901-334
- Custom Integrated Packages from Sun
Notes:
- Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.