You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
XQEGLANDM


$1,113.30

Tags:

  • SUN HYDRAULICS
  • Material:XQEGLANDM
  • Model:XQEG-LAN-DM
  • Summary:Y-assembly

Quantity in stock: 0

***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics XQEGLANDM (XQEGLANDM) is a sophisticated valve assembly designed specifically for charging accumulators using a fixed displacement pump. This assembly operates by unloading the pump when the pressure reaches a predetermined set point and reactivating it when the pressure drops to a specified level, determined by the pilot valve's fixed percentage. It features a ventable relief that functions both as a main stage for pump unloading and as an overpressure relief system. Additionally, it includes mechanisms to soften the pump's unloading process and options for remote sensing of accumulator pressure, which is highly recommended to minimize errors on the accumulator side of the circuit. For optimal performance, this assembly requires a separate drain line to prevent erratic operation due to tank line pressure fluctuations. The choice of adjustment range is crucial; low operating pressures with low differentials can create narrow bands between unload and reset points, necessitating precise system design. High flow rates can result in significant pressure drops that affect valve operation. The porting is intentionally large relative to its capacity to encourage using large piping, thereby reducing flow-induced pressure drop issues. This assembly has a capacity of 20 gpm (80 L/min) and features a check cracking pressure of 50 psi (3.5 bar). It is intended for line mount applications with dimensions accommodating .41 in. (10.4 mm) mounting hole diameter and through-hole depth, requiring 22 holes for secure installation. The spool design ensures consistent differential ratios due to diameters on the spool that are resistant to wear over time, making it reliable for maintaining performance standards throughout usage.

This valve assembly is meant to charge an accumulator using a fixed displacement pump. When the pressure reaches the set point of the valve, the pump is unloaded. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the pump is brought back on line to recharge the accumulator. The ventable relief serves a dual purpose as a main stage to unload the pump and as a system over-pressure relief. The assembly has two additional features; a simple circuit that softens the unloading of the pump and provisions for remote sensing of the accumulator pressure.

  • When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
  • NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
  • The pressure setting and the resultant reseat pressure are in reference to the port 1 area of the QPA* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow. Use of the remote sense for accumulator pressure will minimize the error on the accumulator side of the circuit. Use of the remote sense is highly recommended.
  • The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
  • The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
  • The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
  • The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.

Capacity20 gpm80 L/min.
Check Cracking Pressure50 psi3,5 bar
Body TypeLine mountLine mount
Mounting Hole Diameter.41 in.10,4 mm
Mounting Hole DepthThroughThrough
Mounting Hole Quantity22

Show FAQ

Additional Resources



Notes:
  • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.