SUN HYDRAULICS
XQEGLANCX
$1,114.10 USD
Tags:
- SUN HYDRAULICS
- Material:XQEGLANCX
- Model:XQEG-LAN-CX
- Summary:Y-assembly
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics XQEGLANCX (XQEGLANCX) is a sophisticated valve assembly designed to efficiently manage accumulator charging using a fixed displacement pump. This system operates by unloading the pump when the pressure reaches a predetermined set point, and re-engaging it when the pressure drops to a level defined by the pilot valve's fixed percentage. Key features include a ventable relief that functions both as an overpressure relief and as the main stage for unloading the pump, alongside mechanisms for softening pump unloading and enabling remote sensing of accumulator pressure. It's crucial to incorporate a separate drain line during installation to avoid erratic operations due to tank line pressure fluctuations. When implementing this assembly, it's important to carefully select an appropriate adjustment range as system pressure drops and flow rates can influence unloading valve operations. Low operating pressures with narrow differentials require precise design, while high flow rates can cause significant pressure drops affecting valve performance. The assembly's porting is intentionally large relative to its capacity, encouraging the use of large piping to minimize issues from flow-induced pressure drops. The pilot valve's spool design maintains a fixed differential ratio through durable diameters that resist wear over time. For optimal performance, set the accumulator pilot valve below any system reliefs on the pump side to prevent overheating, and use remote sensing for accurate accumulator pressure readings. The relief in this package acts solely as an overpressure device with settings capped higher than those of the pilot valve. This line-mounted assembly supports capacities up to 20 gpm (80 L/min) with specific mounting hole dimensions provided for secure installation.
The Sun Hydraulics XQEGLANCX (XQEGLANCX) is a sophisticated valve assembly designed to efficiently manage accumulator charging using a fixed displacement pump. This system operates by unloading the pump when the pressure reaches a predetermined set point, and re-engaging it when the pressure drops to a level defined by the pilot valve's fixed percentage. Key features include a ventable relief that functions both as an overpressure relief and as the main stage for unloading the pump, alongside mechanisms for softening pump unloading and enabling remote sensing of accumulator pressure. It's crucial to incorporate a separate drain line during installation to avoid erratic operations due to tank line pressure fluctuations. When implementing this assembly, it's important to carefully select an appropriate adjustment range as system pressure drops and flow rates can influence unloading valve operations. Low operating pressures with narrow differentials require precise design, while high flow rates can cause significant pressure drops affecting valve performance. The assembly's porting is intentionally large relative to its capacity, encouraging the use of large piping to minimize issues from flow-induced pressure drops. The pilot valve's spool design maintains a fixed differential ratio through durable diameters that resist wear over time. For optimal performance, set the accumulator pilot valve below any system reliefs on the pump side to prevent overheating, and use remote sensing for accurate accumulator pressure readings. The relief in this package acts solely as an overpressure device with settings capped higher than those of the pilot valve. This line-mounted assembly supports capacities up to 20 gpm (80 L/min) with specific mounting hole dimensions provided for secure installation.
This valve assembly is meant to charge an accumulator using a fixed displacement pump. When the pressure reaches the set point of the valve, the pump is unloaded. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the pump is brought back on line to recharge the accumulator. The ventable relief serves a dual purpose as a main stage to unload the pump and as a system over-pressure relief. The assembly has two additional features; a simple circuit that softens the unloading of the pump and provisions for remote sensing of the accumulator pressure.
- When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
- NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
- The pressure setting and the resultant reseat pressure are in reference to the port 1 area of the QPA* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow. Use of the remote sense for accumulator pressure will minimize the error on the accumulator side of the circuit. Use of the remote sense is highly recommended.
- The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
- The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
- The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
- The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.
Capacity | 20 gpm80 L/min. |
Check Cracking Pressure | 50 psi3,5 bar |
Body Type | Line mountLine mount |
Mounting Hole Diameter | .41 in.10,4 mm |
Mounting Hole Depth | ThroughThrough |
Mounting Hole Quantity | 22 |
Show FAQ
Additional Resources
- Integrated Packages: Solutions That Grow Your Reputation
- Fluid and Temperature Recommendations
- Sun's Floating Style Screw-In Cartridge
- Sun Model Code Explanation; 999-901-334
- Custom Integrated Packages from Sun
Notes:
- Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.