***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics XQEGLANCL (Material Number: XQEGLANCL) is a comprehensive valve assembly designed specifically for charging an accumulator using a fixed displacement pump. This assembly operates by unloading the pump when the system pressure reaches a predetermined set point, and re-engages the pump to recharge the accumulator once the pressure drops to a specific value set by the pilot valve. The ventable relief feature serves both as an overpressure relief and as a main stage for unloading the pump. Notably, this assembly includes additional features such as a circuit to soften pump unloading and provisions for remote sensing of accumulator pressure, enhancing its operational efficiency. For optimal performance, it is crucial to implement a separate drain line to mitigate erratic operations due to tank line pressure fluctuations. Users should carefully select an appropriate adjustment range, considering that system pressure drops and flow rates can significantly impact unloading valve operations. The design ensures that low operating pressures combined with narrow differentials necessitate precise system calibration. Additionally, high flow rates may result in substantial pressure drops, affecting valve differential capabilities. The assembly's porting is intentionally large relative to its capacity to encourage the use of large piping, thereby minimizing issues caused by flow-induced pressure drops. The spool design of the pilot valve maintains a consistent differential ratio due to its durable construction, which remains unaffected by wear over time. It is essential to adjust the accumulator pilot valve below any reliefs on the pump side of the system to prevent potential overheating. This assembly has a capacity of 20 gpm (80 L/min) and features line mount body type with 22 mounting holes each having a diameter of .41 inches (10.4 mm). The check cracking pressure is set at 50 psi (3.5 bar), ensuring reliable performance in hydraulic systems requiring precise control and safety measures.

This valve assembly is meant to charge an accumulator using a fixed displacement pump. When the pressure reaches the set point of the valve, the pump is unloaded. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the pump is brought back on line to recharge the accumulator. The ventable relief serves a dual purpose as a main stage to unload the pump and as a system over-pressure relief. The assembly has two additional features; a simple circuit that softens the unloading of the pump and provisions for remote sensing of the accumulator pressure.

  • When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
  • NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
  • The pressure setting and the resultant reseat pressure are in reference to the port 1 area of the QPA* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow. Use of the remote sense for accumulator pressure will minimize the error on the accumulator side of the circuit. Use of the remote sense is highly recommended.
  • The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
  • The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
  • The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
  • The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.

Capacity20 gpm80 L/min.
Check Cracking Pressure50 psi3,5 bar
Body TypeLine mountLine mount
Mounting Hole Diameter.41 in.10,4 mm
Mounting Hole DepthThroughThrough
Mounting Hole Quantity22

Show FAQ

Additional Resources



Notes:
  • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.