***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics XQEGLANBL (XQEGLANBL) is a valve assembly designed for efficient accumulator charging using a fixed displacement pump. This sophisticated system automatically unloads the pump when the pressure reaches a predetermined set point, and it re-engages the pump to recharge the accumulator when pressure falls to a specific level determined by the pilot valve's fixed percentage. The ventable relief feature serves dual functions: unloading the pump as a main stage and acting as an overpressure relief for the system. An innovative circuit design softens pump unloading, while remote sensing provisions enhance accumulator pressure monitoring. For optimal performance, this assembly requires a separate drain line to avoid erratic operations due to tank line pressure fluctuations. Selecting an appropriate adjustment range is crucial because low operating pressures and differentials can create narrow bands between unload and reset points, necessitating precise system design. High flow rates often result in significant pressure drops, impacting valve efficiency. The pressure settings are referenced to the QPA pilot valve's port 1 area, with pump and accumulator pressures adjusted for flow-induced drops. Utilizing remote sensing minimizes errors on the accumulator side. The large porting relative to capacity encourages using large piping to mitigate flow-induced pressure drop issues. The pilot valve's spool design maintains a consistent differential ratio due to non-wearing diameter areas on the spool. It's essential that the accumulator pilot valve is set below any system reliefs on the pump side to prevent overheating. The included relief acts as an overpressure device, set higher than any pilot valve adjustments and capped for safety. This assembly handles capacities up to 20 gpm (80 L/min) with a check cracking pressure of 50 psi (3.5 bar). It features line mount body type with through mounting holes measuring .41 inches (10.4 mm) in diameter, requiring 22 mounting holes in total for secure installation.

This valve assembly is meant to charge an accumulator using a fixed displacement pump. When the pressure reaches the set point of the valve, the pump is unloaded. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the pump is brought back on line to recharge the accumulator. The ventable relief serves a dual purpose as a main stage to unload the pump and as a system over-pressure relief. The assembly has two additional features; a simple circuit that softens the unloading of the pump and provisions for remote sensing of the accumulator pressure.

  • When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
  • NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
  • The pressure setting and the resultant reseat pressure are in reference to the port 1 area of the QPA* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow. Use of the remote sense for accumulator pressure will minimize the error on the accumulator side of the circuit. Use of the remote sense is highly recommended.
  • The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
  • The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
  • The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
  • The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.

Capacity20 gpm80 L/min.
Check Cracking Pressure50 psi3,5 bar
Body TypeLine mountLine mount
Mounting Hole Diameter.41 in.10,4 mm
Mounting Hole DepthThroughThrough
Mounting Hole Quantity22

Show FAQ

Additional Resources



Notes:
  • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.