***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics XQEGLANAW (XQEGLANAW) is a specialized valve assembly designed for efficient accumulator charging using a fixed displacement pump. This assembly operates by unloading the pump when the system pressure reaches a predetermined set point and reactivating it when the pressure drops to a specific level, ensuring the accumulator is recharged. A ventable relief valve within the assembly provides dual functionality as both a main stage for unloading the pump and as an overpressure relief system. Two additional features enhance its utility: a simple circuit for softening pump unloading and provisions for remote sensing of accumulator pressure, which is highly recommended to minimize error on the accumulator side. For optimal performance, it's crucial to incorporate a separate drain line to avoid erratic operations due to tank line pressure fluctuations. Additionally, careful selection of adjustment range is necessary since system pressure drops and flow rates significantly influence unloading valve operations. The assembly's porting is intentionally large relative to its capacity, promoting the use of large piping to reduce flow-induced pressure drops. The spool design of the pilot valve maintains a fixed differential ratio, enhancing durability as it resists wear over time. This line-mounted assembly supports up to 20 gpm (80 L/min) capacity with check cracking pressure at 50 psi (3.5 bar). It requires precise setting below any reliefs on the pump side to prevent excessive heating and ensure efficient operation. The overpressure relief in this package is preset higher than the pilot valve\u2019s highest setting and capped for safety reasons. Overall, this robust solution addresses key needs in hydraulic systems requiring reliable accumulator charging and pressure regulation capabilities.

This valve assembly is meant to charge an accumulator using a fixed displacement pump. When the pressure reaches the set point of the valve, the pump is unloaded. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the pump is brought back on line to recharge the accumulator. The ventable relief serves a dual purpose as a main stage to unload the pump and as a system over-pressure relief. The assembly has two additional features; a simple circuit that softens the unloading of the pump and provisions for remote sensing of the accumulator pressure.

  • When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
  • NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
  • The pressure setting and the resultant reseat pressure are in reference to the port 1 area of the QPA* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow. Use of the remote sense for accumulator pressure will minimize the error on the accumulator side of the circuit. Use of the remote sense is highly recommended.
  • The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
  • The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
  • The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
  • The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.

Capacity20 gpm80 L/min.
Check Cracking Pressure50 psi3,5 bar
Body TypeLine mountLine mount
Mounting Hole Diameter.41 in.10,4 mm
Mounting Hole DepthThroughThrough
Mounting Hole Quantity22

Show FAQ

Additional Resources



Notes:
  • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.