You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
XQEGLANAL


$1,126.50 USD

Tags:

  • SUN HYDRAULICS
  • Material:XQEGLANAL
  • Model:XQEG-LAN-AL
  • Summary:Y-assembly

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics XQEGLANAL (XQEGLANAL) is a sophisticated valve assembly designed to efficiently charge an accumulator using a fixed displacement pump. This assembly automatically manages the pump operation by unloading it once the pressure reaches a predetermined set point and re-engaging it when the pressure drops to a specific level, which is determined by the pilot valve's fixed percentage. The ventable relief feature serves as both a main stage for unloading the pump and as an overpressure relief system. Additional functionalities include a circuit that softens the pump's unloading process and provisions for remote sensing of accumulator pressure, which is highly recommended to minimize errors in the accumulator circuit. A separate drain line is necessary to prevent erratic operations due to tank line pressure fluctuations. Selection of an appropriate adjustment range is crucial, as low operating pressures with low differentials can result in narrow bands between unload and reset points, requiring precise system design. The assembly accommodates high flow rates, which typically lead to high pressure drops that affect the differential available for valve operation. The assembly's large porting relative to its capacity encourages using large piping to reduce issues from flow-induced pressure drops. The spool design of the pilot valve maintains a fixed differential ratio due to non-wearing diameters on its spool. It is essential that the accumulator pilot valve is set below any system reliefs on the pump side to avoid severe heating issues. This package includes an overpressure relief device set higher than any pilot valve settings and capped accordingly. With a capacity of 20 gpm (80 L/min) and check cracking pressure at 50 psi (3.5 bar), this line mount body type assembly requires careful consideration of maximum system pressures, especially when constructed from aluminum, which should not exceed 3000 psi (210 bar).

This valve assembly is meant to charge an accumulator using a fixed displacement pump. When the pressure reaches the set point of the valve, the pump is unloaded. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the pump is brought back on line to recharge the accumulator. The ventable relief serves a dual purpose as a main stage to unload the pump and as a system over-pressure relief. The assembly has two additional features; a simple circuit that softens the unloading of the pump and provisions for remote sensing of the accumulator pressure.

  • When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
  • NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
  • The pressure setting and the resultant reseat pressure are in reference to the port 1 area of the QPA* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow. Use of the remote sense for accumulator pressure will minimize the error on the accumulator side of the circuit. Use of the remote sense is highly recommended.
  • The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
  • The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
  • The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
  • The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.

Capacity20 gpm80 L/min.
Check Cracking Pressure50 psi3,5 bar
Body TypeLine mountLine mount
Mounting Hole Diameter.41 in.10,4 mm
Mounting Hole DepthThroughThrough
Mounting Hole Quantity22

Show FAQ

Additional Resources



Notes:
  • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.