You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
XQEFLANEL


$983.50 USD

Tags:

  • SUN HYDRAULICS
  • Material:XQEFLANEL
  • Model:XQEF-LAN-EL
  • Summary:Y-assembly

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics XQEFLANEL (Material Number: XQEFLANEL) is a sophisticated valve assembly designed to efficiently charge an accumulator using a fixed displacement pump. This assembly operates by unloading the pump when the pressure reaches a predetermined set point, and re-engages it once the pressure dips to a specific level determined by the pilot valve's fixed percentage. The ventable relief in this system serves dual roles, acting as both the main stage for unloading the pump and as an overpressure relief mechanism. Additionally, it features a circuit that softens pump unloading, enhancing operational smoothness. When implementing this assembly, it is crucial to incorporate a separate drain line to avoid erratic behavior due to fluctuations in tank line pressure. Attention must be given to selecting an appropriate adjustment range, as system pressure drops and flow rates can significantly impact valve operation. Low pressures combined with minimal differentials necessitate precise system design due to a narrow band between unload and reset points. Conversely, high flow rates can lead to substantial pressure drops. The assembly's porting is deliberately large relative to its capacity, promoting the use of similarly large piping to mitigate issues from flow-induced pressure drops. The pilot valve\u2019s spool design ensures a consistent differential ratio by utilizing diameters that resist wear over time. The accumulator pilot valve should be set below any system reliefs on the pump side to prevent excessive heating. This package's relief component functions as an overpressure device, preset higher than the pilot valve's maximum setting and sealed off for safety. The Sun Hydraulics XQEFLANEL assembly has a capacity of 20 gpm (80 L/min) and is intended for line mounting with specific mounting hole dimensions provided for installation guidance.

This valve assembly is meant to charge an accumulator using a fixed displacement pump. When the pressure reaches the set point of the valve, the pump is unloaded. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the pump is brought back on line to recharge the accumulator. The ventable relief serves a dual purpose as a main stage to unload the pump and as a system over-pressure relief. The assembly has an additional feature; a simple circuit that softens the unloading of the pump.

  • When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
  • NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
  • The pressure setting and the resultant reseat pressure are in reference to the port 2 area of the QCD* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow.
  • The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
  • The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
  • The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
  • The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.

Capacity20 gpm80 L/min.
Body TypeLine mountLine mount
Mounting Hole Diameter.41 in.10,4 mm
Mounting Hole DepthThroughThrough
Mounting Hole Quantity22

Show FAQ

Additional Resources



Notes:
  • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.