***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics XQEFLANDM (Material Number: XQEFLANDM) is a sophisticated valve assembly designed to efficiently manage the charging of an accumulator using a fixed displacement pump. This assembly operates by unloading the pump when the pressure reaches a predefined set point and re-engaging it when the pressure falls to a specific level, determined by the pilot valve's fixed percentage. It features a ventable relief that serves dual purposes: acting as the main stage for unloading the pump and providing system overpressure relief. An additional circuit within this assembly softens pump unloading, ensuring smoother operation. A critical aspect of deploying this valve assembly is incorporating a separate drain line to avoid erratic behavior due to tank line pressure fluctuations. System designers must carefully choose an adjustment range, as low operating pressures combined with low differentials can result in narrow bands between unload and reset, necessitating precise system design. The assembly is capable of handling capacities up to 20 gpm (80 L/min) and is designed for line mounting with large porting relative to its capacity, promoting the use of large piping to minimize flow-induced pressure drops. The spool design in the pilot valve maintains a fixed differential ratio due to its construction, which remains stable over time. The accumulator pilot valve must be set below any reliefs on the pump side to prevent overheating issues. The built-in relief mechanism acts as an overpressure device set higher than other system settings and capped for safety. This robust design ensures reliable performance in managing hydraulic systems where maintaining precise pressure control is essential.

This valve assembly is meant to charge an accumulator using a fixed displacement pump. When the pressure reaches the set point of the valve, the pump is unloaded. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the pump is brought back on line to recharge the accumulator. The ventable relief serves a dual purpose as a main stage to unload the pump and as a system over-pressure relief. The assembly has an additional feature; a simple circuit that softens the unloading of the pump.

  • When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
  • NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
  • The pressure setting and the resultant reseat pressure are in reference to the port 2 area of the QCD* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow.
  • The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
  • The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
  • The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
  • The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.

Capacity20 gpm80 L/min.
Body TypeLine mountLine mount
Mounting Hole Diameter.41 in.10,4 mm
Mounting Hole DepthThroughThrough
Mounting Hole Quantity22

Show FAQ

Additional Resources



Notes:
  • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.