SUN HYDRAULICS
XQCKLANDV


$912.20 USD

Tags:

  • SUN HYDRAULICS
  • Material:XQCKLANDV
  • Model:XQCK-LAN-DV
  • Summary:Y-assembly

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics XQCKLANDV (XQCKLANDV) is a versatile valve assembly designed to efficiently charge an accumulator using a fixed displacement pump. It features a ventable priority flow control valve that ensures optimal flow distribution within hydraulic systems. When the system pressure reaches the valve's set point, the priority flow control is vented, allowing full pump flow to be available. Conversely, when pressure drops, the priority flow recharges the accumulator while maintaining system functionality by directing only necessary flow to the accumulator. This assembly includes essential features such as a circuit for softening pump unloading, an overpressure relief system, and a dump valve for accumulator discharge when the pump is powered down. The application of this assembly requires a separate drain line to counteract potential erratic operations due to tank line pressure fluctuations. System designers should carefully select adjustment ranges as low operating pressures and differentials can narrow operational bands between unload and reset points, necessitating precise design considerations. Additionally, high flow rates can lead to significant pressure drops affecting valve performance. The assembly's large porting relative to its capacity encourages using large piping to minimize issues from flow-induced pressure drops. The pilot valve's spool design ensures a fixed differential ratio through non-wearing diameters on the spool. It\u2019s crucial that the accumulator pilot valve setting remains below any reliefs in the pump side of the system to prevent excessive heating. Overall, this Sun Hydraulics assembly provides robust capabilities for managing hydraulic flows and pressures in systems requiring precise control of accumulators and efficient use of pump output, ensuring reliable operation under varying conditions.

This valve assembly is meant to charge an accumulator using a fixed displacement pump. It incorporates a ventable priority flow control valve. When the pressure reaches the set point of the valve, the priority flow control is vented and all of the pump flow is available to the system. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the priority flow is used to recharge the accumulator. Only the priority flow is directed to the accumulator leaving the rest of the pump flow available to the system. The assembly has three additional features; a simple circuit that softens the unloading of the pump, a system over-pressure relief, and a valve that dumps the accumulator when the pump is powered down.

  • When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
  • NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
  • The pressure setting and the resultant reseat pressure are in reference to the port 2 area of the QCD* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow.
  • The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
  • The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
  • The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
  • The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.

Capacity15 gpm60 L/min.
Body TypeLine mountLine mount
Mounting Hole Thread.375-16 UNC - 2B in..375-16 UNC - 2B in.
Mounting Hole Depth.62 in.15,7 mm
Mounting Hole Quantity22

Show FAQ

Additional Resources



Notes:
  • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.