The Sun Hydraulics XQCKLANCV (XQCKLANCV) is a sophisticated valve assembly designed for charging an accumulator using a fixed displacement pump. This assembly features a ventable priority flow control valve that efficiently manages pump flow based on system pressure demands. When the system pressure reaches the set point, the valve vents the priority flow control, making all pump flow available to the system. Conversely, when pressure drops to a predetermined level, only the priority flow recharges the accumulator, allowing excess pump flow to serve other system needs. The assembly includes three key features: a circuit that softens pump unloading, an overpressure relief system, and a valve to discharge the accumulator when the pump is powered down. For optimal performance, it requires a separate drain line to mitigate erratic operations from tank line pressure fluctuations. The adjustment range must be carefully selected considering system pressure drops and flows which can impact unloading valve operations. Low operating pressures with small differentials necessitate precise design due to narrow bands between unload and reset states. High flow rates typically lead to higher pressure drops affecting differential management. The XQCKLANCV's porting is intentionally large relative to its capacity to encourage using large piping and minimize issues from flow-induced pressure drops. Its pilot valve spool design maintains a consistent differential ratio by utilizing non-wearing diameters on the spool. It is essential that the accumulator pilot valve setting remains below any reliefs in the pump side of the system to prevent overheating. The included overpressure relief device is preset higher than any pilot valve settings and capped for safety. This line-mount body type has two mounting holes with threads of .375-16 UNC 2B in., and each hole has a depth of .62 inches (15.7 mm). The maximum capacity of this assembly is 15 gpm (60 L/min).
This valve assembly is meant to charge an accumulator using a fixed displacement pump. It incorporates a ventable priority flow control valve. When the pressure reaches the set point of the valve, the priority flow control is vented and all of the pump flow is available to the system. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the priority flow is used to recharge the accumulator. Only the priority flow is directed to the accumulator leaving the rest of the pump flow available to the system. The assembly has three additional features; a simple circuit that softens the unloading of the pump, a system over-pressure relief, and a valve that dumps the accumulator when the pump is powered down.
- When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
- NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
- The pressure setting and the resultant reseat pressure are in reference to the port 2 area of the QCD* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow.
- The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
- The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
- The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
- The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.
Capacity | 15 gpm60 L/min. |
Body Type | Line mountLine mount |
Mounting Hole Thread | .375-16 UNC - 2B in..375-16 UNC - 2B in. |
Mounting Hole Depth | .62 in.15,7 mm |
Mounting Hole Quantity | 22 |
Show FAQ
Additional Resources
- Integrated Packages: Solutions That Grow Your Reputation
- Sun's Floating Style Screw-In Cartridge
- Sun Model Code Explanation; 999-901-334
- Custom Integrated Packages from Sun
- Fluid and Temperature Recommendations
Notes:
- Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.