***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics XQCKLANCK (Material Number: XQCKLANCK) is a specialized valve assembly designed for charging an accumulator using a fixed displacement pump. This assembly features a ventable priority flow control valve that optimizes system efficiency by directing the entire pump flow to the system once the pressure reaches the set point. When pressure decreases, a fixed percentage of pilot valve operation redirects priority flow to recharge the accumulator, ensuring continuous system availability. The assembly includes three key features: a circuit to soften pump unloading, an overpressure relief mechanism, and a valve for dumping the accumulator when the pump is shut down. For optimal performance, a separate drain line is recommended to mitigate erratic operation due to tank line pressure fluctuations. This valve assembly's design requires careful consideration of system pressure drops and flow rates, as these factors influence unloading valve operations. The spool design of the pilot valve ensures consistent differential ratio maintenance due to non-wearing diameters on the spool. The product's porting is intentionally large relative to its capacity to encourage large piping use, minimizing issues from flow-induced pressure drops. It is crucial that the accumulator pilot valve setting remains below any reliefs in the pump side of the system to prevent excessive heating. The overpressure relief in this package is intended as an emergency device and should be set higher than any pilot valve settings. The XQCKLANCK has a capacity of 15 gpm (60 L/min), with body type as line mount featuring mounting hole threads at .375-16 UNC 2B in., and hole depth at .62 inches (15.7 mm). This robust design ensures reliable performance in demanding applications where precise control of hydraulic systems is required.

This valve assembly is meant to charge an accumulator using a fixed displacement pump. It incorporates a ventable priority flow control valve. When the pressure reaches the set point of the valve, the priority flow control is vented and all of the pump flow is available to the system. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the priority flow is used to recharge the accumulator. Only the priority flow is directed to the accumulator leaving the rest of the pump flow available to the system. The assembly has three additional features; a simple circuit that softens the unloading of the pump, a system over-pressure relief, and a valve that dumps the accumulator when the pump is powered down.

  • When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
  • NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
  • The pressure setting and the resultant reseat pressure are in reference to the port 2 area of the QCD* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow.
  • The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
  • The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
  • The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
  • The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.

Capacity15 gpm60 L/min.
Body TypeLine mountLine mount
Mounting Hole Thread.375-16 UNC - 2B in..375-16 UNC - 2B in.
Mounting Hole Depth.62 in.15,7 mm
Mounting Hole Quantity22

Show FAQ

Additional Resources



Notes:
  • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.