***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics XQCKLANAV (XQCKLANAV) is a specialized valve assembly designed for efficient accumulator charging using a fixed displacement pump. It features a ventable priority flow control valve that, upon reaching a set pressure, redirects all pump flow to the system. When the pressure falls to a specific threshold, determined by the pilot valve's fixed percentage, it recharges the accumulator with priority flow while maintaining system flow. This assembly includes additional functionalities such as a circuit that softens pump unloading, an overpressure relief system, and an accumulator dump valve for when the pump is powered down. For optimal performance, it's crucial to use a separate drain line to avoid erratic operations due to tank line pressure fluctuations. The assembly demands careful adjustment range selection as low operating pressures may lead to narrow unload and reset bands requiring precise design considerations. High flow rates can result in significant pressure drops affecting valve differentials. The design ensures large porting relative to capacity, encouraging larger piping use to mitigate flow-induced pressure drops. The spool design of the pilot valve maintains a consistent differential ratio due to non-wearing diameters on the spool. It's essential that the accumulator pilot valve is set below any system reliefs on the pump side to prevent overheating issues. The included relief mechanism acts as an overpressure safeguard set above the highest pilot valve settings and is capped for security. This assembly has a capacity of 15 gpm (60 L/min) and is line-mounted with two mounting holes threaded at .375-16 UNC 2B in., each with a depth of .62 in (15.7 mm). Proper consideration should be given to system pressures as aluminum manifolds are not rated beyond 3000 psi (210 bar).

This valve assembly is meant to charge an accumulator using a fixed displacement pump. It incorporates a ventable priority flow control valve. When the pressure reaches the set point of the valve, the priority flow control is vented and all of the pump flow is available to the system. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the priority flow is used to recharge the accumulator. Only the priority flow is directed to the accumulator leaving the rest of the pump flow available to the system. The assembly has three additional features; a simple circuit that softens the unloading of the pump, a system over-pressure relief, and a valve that dumps the accumulator when the pump is powered down.

  • When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
  • NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
  • The pressure setting and the resultant reseat pressure are in reference to the port 2 area of the QCD* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow.
  • The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
  • The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
  • The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
  • The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.

Capacity15 gpm60 L/min.
Body TypeLine mountLine mount
Mounting Hole Thread.375-16 UNC - 2B in..375-16 UNC - 2B in.
Mounting Hole Depth.62 in.15,7 mm
Mounting Hole Quantity22

Show FAQ

Additional Resources



Notes:
  • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.