The Sun Hydraulics XQCKLANAC (XQCKLANAC) is a sophisticated valve assembly designed for charging accumulators using a fixed displacement pump. This assembly features a ventable priority flow control valve that operates by venting the priority flow when the system pressure reaches the set point, thus allowing full pump flow to be available to the system. As pressure decreases, determined by a fixed percentage of the pilot valve, the priority flow recharges the accumulator while leaving remaining pump flow for system use. Key features include a circuit that softens pump unloading, an overpressure relief system, and a valve that dumps accumulator pressure when the pump is off. For optimal performance, this assembly requires a separate drain line to mitigate erratic operations due to tank line pressure variations. Selecting an appropriate adjustment range is crucial as low operating pressures combined with low differentials can lead to narrow bands between unload and reset points, necessitating precise system design. The pressure settings are referenced from port 2 of the QCD pilot valve, with pump and accumulator pressures affected by flow-induced pressure drops. The assembly's large porting is intended to accommodate large piping, minimizing issues from flow-induced pressure drops. The spool design ensures consistent differential ratios as it maintains fixed areas unaffected by wear. It\u2019s important that the accumulator pilot valve is set below any reliefs on the pump side to prevent overheating. The included relief mechanism acts as an overpressure device and is set higher than pilot valve settings. With a capacity of 15 gpm (60 L/min), this line-mount type assembly requires specific mounting hole threads and depths for installation. It utilizes 6061-T651 aluminum for its corrosion resistance and structural integrity without anodizing due to several practical considerations related to cost, logistics, inspection challenges, and fatigue life concerns.
This valve assembly is meant to charge an accumulator using a fixed displacement pump. It incorporates a ventable priority flow control valve. When the pressure reaches the set point of the valve, the priority flow control is vented and all of the pump flow is available to the system. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the priority flow is used to recharge the accumulator. Only the priority flow is directed to the accumulator leaving the rest of the pump flow available to the system. The assembly has three additional features; a simple circuit that softens the unloading of the pump, a system over-pressure relief, and a valve that dumps the accumulator when the pump is powered down.
- When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
- NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
- The pressure setting and the resultant reseat pressure are in reference to the port 2 area of the QCD* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow.
- The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
- The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
- The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
- The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.
Capacity | 15 gpm60 L/min. |
Body Type | Line mountLine mount |
Mounting Hole Thread | .375-16 UNC - 2B in..375-16 UNC - 2B in. |
Mounting Hole Depth | .62 in.15,7 mm |
Mounting Hole Quantity | 22 |
Show FAQ
Additional Resources
- Integrated Packages: Solutions That Grow Your Reputation
- Sun's Floating Style Screw-In Cartridge
- Sun Model Code Explanation; 999-901-334
- Custom Integrated Packages from Sun
- Fluid and Temperature Recommendations
Notes:
- Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.