***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics XQCHLANBV (XQCHLANBV) is a specialized valve assembly designed to efficiently charge an accumulator using a fixed displacement pump. This assembly automatically unloads the pump when the system pressure reaches a predetermined set point and re-engages the pump when the pressure drops, based on a fixed percentage determined by the pilot valve. It features a ventable relief that functions both as an overpressure relief and as the main stage for unloading the pump. Additionally, it incorporates a circuit to soften pump unloading and allows for remote sensing of accumulator pressure. This assembly requires careful consideration of its adjustment range due to potential system pressure drops and flow rates that can affect unloading valve operations. A separate drain line is necessary to prevent erratic behavior from tank line pressure fluctuations. The valve's design ensures that it maintains a consistent differential ratio, thanks to its spool design which resists wear over time. The XQCHLANBV has a capacity of 10 gpm (40 L/min) and is line-mounted with two mounting holes measuring .41 inches (10.4 mm) in diameter. It is important to set the accumulator pilot valve below any reliefs in the pump side of the system to avoid excessive heating. The relief component is intended as an overpressure device, positioned higher than any pilot valve settings. For optimal performance, remote sensing for accumulator pressure is recommended, minimizing potential errors on this side of the circuit. The large porting relative to capacity encourages using larger piping, reducing issues from flow-induced pressure drops. This robust assembly supports precise system design by balancing high flow rates with adequate pressure management.

This valve assembly is meant to charge an accumulator using a fixed displacement pump. When the pressure reaches the set point of the valve, the pump is unloaded. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the pump is brought back on line to recharge the accumulator. The ventable relief serves a dual purpose as a main stage to unload the pump and as a system over-pressure relief. The assembly has two additional features; a simple circuit that softens the unloading of the pump and provisions for remote sensing of the accumulator pressure.

  • When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
  • NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
  • The pressure setting and the resultant reseat pressure are in reference to the port 1 area of the QPA* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow. Use of the remote sense for accumulator pressure will minimize the error on the accumulator side of the circuit. Use of the remote sense is highly recommended.
  • The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
  • The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
  • The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
  • The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.

Capacity10 gpm40 L/min.
Body TypeLine mountLine mount
Mounting Hole Diameter.41 in.10,4 mm
Mounting Hole DepthThroughThrough
Mounting Hole Quantity22

Show FAQ

Additional Resources



Notes:
  • Some applications may require additional volume for a smoother shift. Should this become necessary, an auxillary port has been provided to attach a length of hose for additional volume.
  • Remote sensing of accumlator charge pressure can be achieved by interchanging cavity plugs XZCC and XZOC, and connecting RS port to Accumulator.
  • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.