***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics XQCHLANBC (Material Number: XQCHLANBC) is a sophisticated valve assembly designed for charging an accumulator using a fixed displacement pump. This assembly effectively manages the pump's operation by unloading it when the pressure reaches a predetermined set point and re-engaging it to recharge the accumulator when the pressure drops to a specified level. It features a ventable relief that functions both as a main stage for unloading the pump and as an overpressure relief for the system. The design includes mechanisms to soften pump unloading and allows for remote sensing of accumulator pressure, ensuring precise system control. A separate drain line is necessary to prevent erratic operation due to tank line pressure fluctuations. Selecting an appropriate adjustment range is crucial, as low operating pressures and high flow rates can affect valve performance, necessitating careful system design. The valve's pressure setting is relative to the port 1 area of the QPA pilot valve, with remote sensing recommended to minimize errors in accumulator pressure readings. The assembly's large porting encourages using large piping, reducing issues from flow-induced pressure drops. Its spool design maintains a consistent differential ratio, enhancing durability by preventing wear-related changes. It's essential that the accumulator pilot valve be set below any pump-side reliefs to avoid excessive heating. This package's relief acts as an overpressure device set higher than the pilot valve\u2019s maximum setting. With a capacity of 10 gpm (40 L/min), this line mount body type requires specific mounting hole dimensions and quantities for installation. This product serves applications requiring reliable hydraulic control with precise adjustments and robust performance characteristics.

This valve assembly is meant to charge an accumulator using a fixed displacement pump. When the pressure reaches the set point of the valve, the pump is unloaded. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the pump is brought back on line to recharge the accumulator. The ventable relief serves a dual purpose as a main stage to unload the pump and as a system over-pressure relief. The assembly has two additional features; a simple circuit that softens the unloading of the pump and provisions for remote sensing of the accumulator pressure.

  • When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
  • NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
  • The pressure setting and the resultant reseat pressure are in reference to the port 1 area of the QPA* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow. Use of the remote sense for accumulator pressure will minimize the error on the accumulator side of the circuit. Use of the remote sense is highly recommended.
  • The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
  • The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
  • The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
  • The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.

Capacity10 gpm40 L/min.
Body TypeLine mountLine mount
Mounting Hole Diameter.41 in.10,4 mm
Mounting Hole DepthThroughThrough
Mounting Hole Quantity22

Show FAQ

Additional Resources



Notes:
  • Some applications may require additional volume for a smoother shift. Should this become necessary, an auxillary port has been provided to attach a length of hose for additional volume.
  • Remote sensing of accumlator charge pressure can be achieved by interchanging cavity plugs XZCC and XZOC, and connecting RS port to Accumulator.
  • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.