***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics XQCFLANCC (XQCFLANCC) is a sophisticated valve assembly designed specifically for accumulator charging using a fixed displacement pump. This assembly excels in managing pressure by unloading the pump when the pressure reaches a predetermined set point and re-engaging it to recharge when the pressure drops. It features a ventable relief that functions both as a main stage to unload the pump and as an overpressure relief system, ensuring dual functionality. Additionally, it incorporates a simple circuit to soften pump unloading, enhancing operational smoothness. When implementing this assembly, it is crucial to utilize a separate drain line to avoid erratic performance due to tank line pressure fluctuations. The selection of an appropriate adjustment range demands careful consideration since system pressure drops and flow rates influence the operation of unloading valves. Specifically, low operating pressures with minimal differentials require precise system design due to the narrow band between unload and reset points. Conversely, high flow rates can result in significant pressure drops, affecting the differential available for valve operation. The pressure settings are referenced from port 2 of the QCD pilot valve; hence, pump and accumulator pressures may vary due to flow-induced pressure drops. The assembly's large porting encourages using similarly large piping to mitigate issues related to flow-induced pressure drops. The pilot valve's spool design ensures a fixed differential ratio by maintaining consistent areas on non-wearing spool diameters. In terms of capacity, this line-mount body type assembly supports up to 10 gpm (40 L/min). It requires two mounting holes with a diameter of .41 inches (10.4 mm), drilled through completely for secure installation. This product is engineered for robust hydraulic applications where precision and reliability are paramount.
The Sun Hydraulics XQCFLANCC (XQCFLANCC) is a sophisticated valve assembly designed specifically for accumulator charging using a fixed displacement pump. This assembly excels in managing pressure by unloading the pump when the pressure reaches a predetermined set point and re-engaging it to recharge when the pressure drops. It features a ventable relief that functions both as a main stage to unload the pump and as an overpressure relief system, ensuring dual functionality. Additionally, it incorporates a simple circuit to soften pump unloading, enhancing operational smoothness. When implementing this assembly, it is crucial to utilize a separate drain line to avoid erratic performance due to tank line pressure fluctuations. The selection of an appropriate adjustment range demands careful consideration since system pressure drops and flow rates influence the operation of unloading valves. Specifically, low operating pressures with minimal differentials require precise system design due to the narrow band between unload and reset points. Conversely, high flow rates can result in significant pressure drops, affecting the differential available for valve operation. The pressure settings are referenced from port 2 of the QCD pilot valve; hence, pump and accumulator pressures may vary due to flow-induced pressure drops. The assembly's large porting encourages using similarly large piping to mitigate issues related to flow-induced pressure drops. The pilot valve's spool design ensures a fixed differential ratio by maintaining consistent areas on non-wearing spool diameters. In terms of capacity, this line-mount body type assembly supports up to 10 gpm (40 L/min). It requires two mounting holes with a diameter of .41 inches (10.4 mm), drilled through completely for secure installation. This product is engineered for robust hydraulic applications where precision and reliability are paramount.
This valve assembly is meant to charge an accumulator using a fixed displacement pump. When the pressure reaches the set point of the valve, the pump is unloaded. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the pump is brought back on line to recharge the accumulator. The ventable relief serves a dual purpose as a main stage to unload the pump and as a system over-pressure relief. The assembly has an additional feature; a simple circuit that softens the unloading of the pump.
- When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
- NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
- The pressure setting and the resultant reseat pressure are in reference to the port 2 area of the QCD* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow.
- The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
- The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
- The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
- The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.
| Capacity | 10 gpm40 L/min. |
| Body Type | Line mountLine mount |
| Mounting Hole Diameter | .41 in.10,4 mm |
| Mounting Hole Depth | ThroughThrough |
| Mounting Hole Quantity | 22 |
Show FAQ
Additional Resources
- Integrated Packages: Solutions That Grow Your Reputation
- Fluid and Temperature Recommendations
- Sun's Floating Style Screw-In Cartridge
- Sun Model Code Explanation; 999-901-334
- Custom Integrated Packages from Sun
Notes:
- Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.