***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics XQCFLANAV (Material Number: XQCFLANAV) is a valve assembly designed for charging an accumulator using a fixed displacement pump. It operates by unloading the pump when the pressure reaches a pre-set point and re-engages it when pressure drops to a specified level, determined by the pilot valve's fixed percentage. This dual-purpose ventable relief valve not only unloads the pump but also serves as an overpressure relief system. An additional feature of this assembly is a circuit that softens the pump's unloading process, enhancing operational smoothness. For optimal performance, it requires a separate drain line to avoid erratic behavior caused by fluctuations in tank line pressure. When implementing this assembly, careful selection of adjustment range is crucial due to potential system pressure drops and flow effects on unloading valves. Low operating pressures combined with narrow differentials necessitate precise system design to maintain stability between unload and reset phases. High flow rates can lead to significant pressure drops, affecting the valve's differential capacity. The assembly's large porting relative to its capacity encourages using large piping to minimize issues from flow-induced pressure drops. The pilot valve's spool design ensures a consistent differential ratio, as its areas are determined by spool diameters that resist wear over time. It's essential to set the accumulator pilot valve below any reliefs on the pump side to prevent excessive heating. The included relief mechanism acts as an overpressure device, positioned higher than any pilot valve setting and capped for safety. Key specifications include a capacity of 10 gpm (40 L/min), line mount body type, two mounting holes with .41 in (10.4 mm) diameter through-holes for secure installation, ensuring robust performance in hydraulic systems requiring precise accumulator charging control.

This valve assembly is meant to charge an accumulator using a fixed displacement pump. When the pressure reaches the set point of the valve, the pump is unloaded. When the pressure drops to the value determined by the fixed percentage of the pilot valve, the pump is brought back on line to recharge the accumulator. The ventable relief serves a dual purpose as a main stage to unload the pump and as a system over-pressure relief. The assembly has an additional feature; a simple circuit that softens the unloading of the pump.

  • When applying this assembly, a separate drain line is required to prevent erratic operation caused by tank line pressure fluctuations.
  • NOTE: Careful consideration should be given when selecting an adjustment range. System pressure drops and flows tend to affect the operation of unloading valves. Low operating pressures combined with low differentials result in a very narrow band between unload and reset, requiring precise system design. High flow rates typically mean high pressure drops, which subtract from the differential the valve has to work with.
  • The pressure setting and the resultant reseat pressure are in reference to the port 2 area of the QCD* pilot valve. Pump pressure will be higher and accumulator pressure will be lower due to pressure drop caused by flow.
  • The porting on this assembly is large in relation to its capacity. This is done to encourage the use of correspondingly large piping to minimize problems caused by flow induced pressure drop.
  • The spool design of the pilot valve allows it to maintain a fixed differential ratio because the areas are created by diameters on the spool that will not wear or change with use.
  • The accumulator pilot valve must be set below any reliefs in the pump side of the system or severe heating could occur.
  • The relief in this package is meant to be an over-pressure device. It is set higher than the highest setting of the pilot valve and capped.

Capacity10 gpm40 L/min.
Body TypeLine mountLine mount
Mounting Hole Diameter.41 in.10,4 mm
Mounting Hole DepthThroughThrough
Mounting Hole Quantity22

Show FAQ

Additional Resources



Notes:
  • Important: Carefully consider the maximum system pressure. The pressure rating of the manifold is dependent on the manifold material, with the port type/size a secondary consideration. Manifolds constructed of aluminum are not rated for pressures higher than 3000 psi (210 bar), regardless of the port type/size specified.