***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics SXCBKDV (SXCBKDV) is an atmospherically referenced, direct-acting sequence valve designed to supply a secondary circuit with flow once the pressure at inlet port 1 exceeds the valve setting. This sequence valve controls the pressure at port 1 relative to the atmospheric vent and is suitable for load holding applications. It incorporates Sun's floating style construction, minimizing potential binding of internal parts due to excessive installation torque or machining variations. The valve features a cavity T-13A series 1 with a capacity of 15 gpm (60 L/min) and operates at a maximum pressure of 5000 psi (350 bar). It offers a typical response time of 2 ms and has a maximum leakage rate of 10 drops/min (0.7 cc/min) upon reseat. The adjustment mechanism allows for increasing settings with up to four turns clockwise, while installation requires a torque of 30\u201335 lbf ft (41\u201347 Nm). The adjustment screw has an internal hex size of 5/32 in. (4 mm), and the locknut requires a torque of 80\u201390 lbf in. (9\u201310 Nm). Weighing approximately .30 lb (.15 kg), this model includes Viton seals as part of its cartridge seal kit, ensuring durability and performance in various conditions.

Atmospherically referenced, direct-acting sequence valves will supply a secondary circuit with flow once the pressure at the inlet (port 1) has exceeded the valve setting. The pressure setting of this sequence valve controls the pressure at port 1 relative to the atmospheric vent.

  • Suitable for use in load holding applications.
  • Atmospherically referenced valves should only be used where it is impossible have a drain connection. Over time, the atmospherically referenced valves may leak externally or allow moisture into the spring chamber.
  • Approximately 1 drop (0,07 cc) of fluid will pass into the vented spring chamber every 4000 cycles.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-13A
Series1
Capacity15 gpm60 L/min.
Factory Pressure Settings Established at2 in³/min.30 cc/min.
Maximum Operating Pressure5000 psi350 bar
Response Time - Typical2 ms2 ms
Maximum Valve Leakage at Reseat10 drops/min.0,7 cc/min.
Adjustment - Number of Clockwise Turns to Increase Setting44
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.30 lb0,15 kg
Seal kit - CartridgeViton: 990-010-006

Show FAQ