SUN HYDRAULICS
RVEBCDV
$161.90 USD
Tags:
- SUN HYDRAULICS
- Material:RVEBCDV
- Model:RVEB-CDV
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics RVEBCDV (RVEBCDV) is a versatile three-port normally closed modulating element with relief, designed to perform dual functions when combined with an external orifice. Primarily, it acts as a bypass compensator, managing priority flow into a circuit as determined by the external orifice. Any input flow that exceeds this priority is redirected to tank port 2. Additionally, when inlet port 1 pressure surpasses the valve setting, it functions as a standard relief valve. The compensating pressure across all ranges is maintained at 120 psi (8 bar). Performance curves indicate system pressure on the X-axis and the resultant pressure differential across the control orifice on the Y-axis, highlighting various bypass flows where capacity and performance are dictated by bypass flow rather than control flow. The valve features adjustable W and Y controls, allowing for full-range adjustment unless specified otherwise for a special setting, which indicates the valve's maximum setting. It fits into a T-2A cavity series with a capacity of 20 gpm (80 L/min) and can withstand a maximum operating pressure of 5000 psi (350 bar). Typical response time is around 10 ms with minimal leakage at specified conditions. The valve requires specific installation torque values and adjustment parameters for optimal performance. With a model weight of .70 lb (.30 kg), it includes an internal hex size adjustment screw and locknut for secure settings. A Viton seal kit (990202006) is available for this cartridge model to ensure reliable sealing in hydraulic applications.
The Sun Hydraulics RVEBCDV (RVEBCDV) is a versatile three-port normally closed modulating element with relief, designed to perform dual functions when combined with an external orifice. Primarily, it acts as a bypass compensator, managing priority flow into a circuit as determined by the external orifice. Any input flow that exceeds this priority is redirected to tank port 2. Additionally, when inlet port 1 pressure surpasses the valve setting, it functions as a standard relief valve. The compensating pressure across all ranges is maintained at 120 psi (8 bar). Performance curves indicate system pressure on the X-axis and the resultant pressure differential across the control orifice on the Y-axis, highlighting various bypass flows where capacity and performance are dictated by bypass flow rather than control flow. The valve features adjustable W and Y controls, allowing for full-range adjustment unless specified otherwise for a special setting, which indicates the valve's maximum setting. It fits into a T-2A cavity series with a capacity of 20 gpm (80 L/min) and can withstand a maximum operating pressure of 5000 psi (350 bar). Typical response time is around 10 ms with minimal leakage at specified conditions. The valve requires specific installation torque values and adjustment parameters for optimal performance. With a model weight of .70 lb (.30 kg), it includes an internal hex size adjustment screw and locknut for secure settings. A Viton seal kit (990202006) is available for this cartridge model to ensure reliable sealing in hydraulic applications.
Three-port normally closed modulating elements with relief provide two functions when combined with an external orifice. The mainstage is a bypass compensator that controls a priority flow into the circuit, determined by the external orifice. Input flow in excess of the priority flow is bypassed to tank (port 2). If the inlet (port 1) pressure rises to the valve setting, the valve operates as a normal relief valve.
- Compensating pressure for all ranges is 120 psi (8 bar).
- Explanation of the performance curve: The X axis is system pressure. The Y axis shows the pressure differential that the valve creates across the control orifice. The curves represent various bypass flows (pump flow minus control flow). The capacity and performance of this valve is determined by the bypass flow, control flow is not a factor.
- W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
| Cavity | T-2A |
| Series | 2 |
| Capacity | 20 gpm80 L/min. |
| Factory Pressure Settings Established at | 4 gpm15 L/min. |
| Maximum Operating Pressure | 5000 psi350 bar |
| Response Time - Typical | 10 ms10 ms |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 3 in³/min.@1000 psi50 cc/min.@70 bar |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 1 1/8 in.28,6 mm |
| Valve Installation Torque | 45 - 50 lbf ft61 - 68 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .70 lb0,30 kg |
| Seal kit - Cartridge | Viton: 990-202-006 |
Show FAQ
Additional Resources
- Sun Cartridges with EPDM Seals
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Sun Expands Corrosion-Resistant Solutions
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Manufacturing Sun Cartridge Cavities
- Cartridges: Materials of Construction
- Cavity Information (S-171) and Tooling
- Fluid and Temperature Recommendations
- Sun's Floating Style Screw-In Cartridge
- Performance Data
- Sun Model Code Explanation; 999-901-334
- Units of Measure, Settings, and Conversions