***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics RVCDKDV (RVCDKDV) is a ventable, pilot-operated, balanced piston relief cartridge with an external drain designed for precise pressure regulation. This normally closed valve opens to the tank port when the inlet pressure reaches the set level, allowing flow throttling to maintain consistent pressure. It features a vent port for remote control and a drain port that ensures insensitivity to back pressure. The RVCDKDV is accurate, with low pressure rise versus flow, smooth operation, and moderate speed. It can accept maximum pressure at port 2 and is suitable for cross-port relief circuits, although spool leakage should be considered in such applications. The main stage orifice is protected by a 150-micron stainless steel screen, but it is not suitable for load-holding applications due to potential leakage. Pressure at port 4 directly affects the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar). Cartridges with EPDM seals are intended for systems using phosphate ester fluids and are incompatible with petroleum-based substances. The valve can be adjusted throughout its range using W or Y controls unless a special setting is specified, which represents the maximum setting. It incorporates Sun's floating style construction to reduce binding risks from installation torque or machining variations. Specifications include a T-21A cavity series with a capacity of 15 gpm (60 L/min), maximum operating pressure of 5000 psi (350 bar), control pilot flow of 7-10 in\u00b3/min (0.11-0.16 L/min), typical response time of 10 ms, maximum valve leakage at 110 SUS (24 cSt) of 2 in\u00b3/min at 1000 psi (30 cc/min at 70 bar), and adjustment through clockwise turns up to five-and-a-half times for increased settings.

Ventable, pilot-operated, balanced piston relief cartridges with external drain are normally closed pressure regulating valves. When the pressure at the inlet (port 1) reaches the valve setting, the valve starts to open to tank (port 2), throttling flow to regulate the pressure. They provide a vent port (port 3) that connects between the main piston and pilot stage to provide for remote control by other pilot or 2-way valves and a drain (port 4) that makes them insensitive to back pressure. These valves are accurate, have low pressure rise vs. flow, they are smooth and quiet, and are moderately fast.

  • A remote pilot relief on port 3 (vent) will control the valve below its own setting.
  • Will accept maximum pressure at port 2; suitable for use in cross port relief circuits. If used in cross port relief circuits, consider spool leakage.
  • Main stage orifice is protected by a 150 micron stainless steel screen.
  • Not suitable for use in load holding applications due to spool leakage.
  • Pressure at port 4 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-21A
Series1
Capacity15 gpm60 L/min.
Factory Pressure Settings Established at4 gpm15 L/min.
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow7 - 10 in³/min.0,11 - 0,16 L/min.
Response Time - Typical10 ms10 ms
Maximum Valve Leakage at 110 SUS (24 cSt)2 in³/min.@1000 psi30 cc/min.@70 bar
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.40 lb0,20 kg
Seal kit - CartridgeViton: 990-021-006