***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics RVCAKAV (Material Number: RVCAKAV) is a ventable, pilot-operated, balanced piston relief cartridge designed for precise pressure regulation in hydraulic systems. This normally closed valve opens to the tank port when inlet pressure reaches a pre-set level, throttling flow to maintain desired system pressure. It features a vent port that allows remote control via other pilot or two-way valves, enhancing its versatility and control accuracy. The RVCAKAV is characterized by its low pressure rise versus flow, smooth operation, quiet performance, and moderate speed. It is capable of handling maximum pressures at port 2 and is suitable for cross-port relief circuits; however, users should consider spool leakage in such applications. The valve's main stage orifice is safeguarded by a 150-micron stainless steel screen. It's important to note that this cartridge is not suitable for load-holding applications due to potential spool leakage. Additionally, any back pressure on the tank port directly adds to the valve setting at a 1:1 ratio. The RVCAKAV can be equipped with EPDM seals for systems utilizing phosphate ester fluids; exposure to petroleum-based fluids will damage these seals. Incorporating Sun's floating style construction minimizes risks of internal binding due to excessive torque or machining variations during installation. The valve fits into a T-11A cavity and has a capacity of 15 gpm (60 L/min). It operates at up to 5000 psi (350 bar) with a typical response time of 10 ms and maximum leakage of 2 in\u00b3/min (30 cc/min) at specified conditions. Adjustment requires up to five clockwise turns, with specific hex sizes and torque values for installation and adjustment components provided for precise setup.

Ventable, pilot-operated, balanced piston relief cartridges are normally closed pressure regulating valves. When the pressure at the inlet (port 1) reaches the valve setting, the valve starts to open to tank (port 2), throttling flow to regulate the pressure. They provide a vent port (port 3) that connects between the main piston and pilot stage to provide for remote control by other pilot or 2-way valves. These valves are accurate, have low pressure rise vs. flow, they are smooth and quiet, and are moderately fast.

  • A remote pilot relief on port 3 (vent) will control the valve below its own setting.
  • Will accept maximum pressure at port 2; suitable for use in cross port relief circuits. If used in cross port relief circuits, consider spool leakage.
  • Main stage orifice is protected by a 150 micron stainless steel screen.
  • Not suitable for use in load holding applications due to spool leakage.
  • Back pressure on the tank port (port 2) is directly additive to the valve setting at a 1:1 ratio.
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-11A
Series1
Capacity15 gpm60 L/min.
Factory Pressure Settings Established at4 gpm15 L/min.
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow7 - 10 in³/min.0,11 - 0,16 L/min.
Response Time - Typical10 ms10 ms
Maximum Valve Leakage at 110 SUS (24 cSt)2 in³/min.@1000 psi30 cc/min.@70 bar
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.40 lb0,20 kg
Seal kit - CartridgeViton: 990-011-006

Show FAQ

Additional Resources



Notes:
  • For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.