You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
RBANXDV72499


$250.40 USD

Tags:

  • SUN HYDRAULICS
  • Material:RBANXDV72499
  • Model:RBAN-XDV@72499
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics RBANXDV72499 (RBANXDV72499) is a 2-port, pilot-stage, direct-acting relief cartridge valve designed for electroproportional control and pressure regulation. This normally-closed valve is spring-biased to its highest setting, which must be specified by the customer within the selected pressure range. The valve's operation allows for proportional pressure reduction as current increases to the coil, facilitating flow from port 1 to port 2 when inlet pressure surpasses the combined spring and solenoid forces. Utilizing the T8A cavity, this cartridge is compatible with Sun's main stage pressure control elements, eliminating separate pilot lines and requiring only one cavity for both control and primary functions. The high pilot capacity supports larger main stage elements, while damped construction ensures stable performance across various conditions. Notable features include low leakage in the closed position and a reseat occurring at 85% of cracking pressure. The interchangeable coils can be mounted in either direction on the solenoid tube. For optimal functionality, an amplifier with adjustable dither between 100\u2013250 Hz is recommended. Installation requires correct torque application first to the main stage valve followed by the T8A pilot control section. The floating style construction minimizes binding risks due to installation torque or machining variations. With a flow capacity of 0.25 gpm (1 L/min) and maximum operating pressure of 5000 psi (350 bar), this valve integrates seamlessly into systems needing precise electroproportional control of hydraulic pressures.

This 2-port, pilot-stage, direct-acting relief cartridge is an electro-proportionally controlled, normally-closed pressure regulating valve. The valve is spring biased closed to its highest setting (customer specified). Increasing current to the coil will proportionally decrease the pressure setting. When the pressure at port 1 (inlet) is sufficient to overcome the spring force minus the solenoid force, as determined by the analog input signal, the poppet lifts and allows flow from port 1 to port 2 (outlet). This pilot control cartridge utilizes the T-8A cavity so it can be used in conjunction with Sun's main stage, pressure control elements.

  • Customer must specify a relief setting that falls within the selected pressure range. This setting represents the maximum relief pressure which the valve will default to with no command. As the command increases, the relief setting will decrease. See performance curves for selected pressure range. This setting is not adjustable in the field.
  • Varying the analog input signal to the proportional solenoid provides a step-less control of pressure.
  • This electro-proportional cartridge utilizes the Sun T-8A, 2-port cavity making it the ideal choice to use in conjunction with Sun's main stage cartridges. Separate pilot lines are eliminated and only one cavity needs to be machined to accommodate both the control and primary function. Note: All 2-port pilot stage control cartridges utilize the same cavity and are physically interchangeable. Functionality is the only consideration.
  • High pilot capacity allows for operation of larger size main stage elements.
  • Damped construction provides stable operation over a wide range of operating conditions.
  • Low leakage levels in the closed position. (Reseat occurs at 85% of cracking pressure.)
  • Coils are interchangeable with Sun's other full flow, solenoid operated valves and can be mounted on the tube in either direction.
  • For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
  • Note: The main stage valve should first be installed to the correct torque value followed by the T-8A pilot control section into the main stage valve to its required torque value.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-8A
SeriesP
Capacity.25 gpm1 L/min.
Maximum Operating Pressure5000 psi350 bar
Maximum Valve Leakage at Reseat1.5 in³/min.25 cc/min.
Reseat>85% of setting>85% of setting
Solenoid Tube Diameter.75 in.19 mm
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque20 - 25 lbf ft27 - 33 Nm
Model Weight (with coil)1.00 lb0,45 kg
Seal kit - CartridgeViton: 990-208-006
Seal and nut kit - CoilViton: 990-770-006Viton: 990-770-006

Show FAQ

Additional Resources