***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics RBANXBN2B24A (RBANXBN2B24A) is a 2-port, pilot-stage, direct-acting relief cartridge designed for electroproportional control in hydraulic systems. This normally-closed pressure regulating valve is spring-biased to its highest setting, which is specified by the customer. The valve operates by decreasing the pressure setting proportionally as current increases to the coil. When the inlet pressure at port 1 surpasses the combined spring and solenoid forces, determined by an analog input signal, the poppet lifts to allow flow from port 1 to port 2. This pilot control cartridge uses the T8A cavity, making it compatible with Sun's main stage pressure control elements. Customers must specify a relief setting within their selected pressure range, which represents the maximum relief pressure without command input. As commands increase, this relief setting decreases accordingly; however, it cannot be adjusted in the field. Varying analog input signals provide stepless pressure control via the proportional solenoid. The high pilot capacity of this cartridge allows for operation with larger main stage elements while its damped construction ensures stable performance across various conditions. It features low leakage levels when closed and reseats at 85% of cracking pressure. The valve's interchangeable coils can be mounted bidirectionally on the solenoid tube and are compatible with other Sun solenoid-operated valves. Optimal performance requires an amplifier with current sensing and adjustable dither between 100\u2013250 Hz. Installation involves securing the main stage valve first followed by torquing the T8A pilot control section into place to minimize internal binding risks due to torque or machining variations. With a maximum operating pressure of 5000 psi (350 bar) and a capacity of .25 gpm (1 L/min), this versatile cartridge is ideal for precise hydraulic control applications requiring reliable performance and adaptability in system design.

This 2-port, pilot-stage, direct-acting relief cartridge is an electro-proportionally controlled, normally-closed pressure regulating valve. The valve is spring biased closed to its highest setting (customer specified). Increasing current to the coil will proportionally decrease the pressure setting. When the pressure at port 1 (inlet) is sufficient to overcome the spring force minus the solenoid force, as determined by the analog input signal, the poppet lifts and allows flow from port 1 to port 2 (outlet). This pilot control cartridge utilizes the T-8A cavity so it can be used in conjunction with Sun's main stage, pressure control elements.

  • Customer must specify a relief setting that falls within the selected pressure range. This setting represents the maximum relief pressure which the valve will default to with no command. As the command increases, the relief setting will decrease. See performance curves for selected pressure range. This setting is not adjustable in the field.
  • Varying the analog input signal to the proportional solenoid provides a step-less control of pressure.
  • This electro-proportional cartridge utilizes the Sun T-8A, 2-port cavity making it the ideal choice to use in conjunction with Sun's main stage cartridges. Separate pilot lines are eliminated and only one cavity needs to be machined to accommodate both the control and primary function. Note: All 2-port pilot stage control cartridges utilize the same cavity and are physically interchangeable. Functionality is the only consideration.
  • High pilot capacity allows for operation of larger size main stage elements.
  • Damped construction provides stable operation over a wide range of operating conditions.
  • Low leakage levels in the closed position. (Reseat occurs at 85% of cracking pressure.)
  • Coils are interchangeable with Sun's other full flow, solenoid operated valves and can be mounted on the tube in either direction.
  • For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
  • Note: The main stage valve should first be installed to the correct torque value followed by the T-8A pilot control section into the main stage valve to its required torque value.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-8A
SeriesP
Capacity.25 gpm1 L/min.
Maximum Operating Pressure5000 psi350 bar
Maximum Valve Leakage at Reseat1.5 in³/min.25 cc/min.
Reseat>85% of setting>85% of setting
Solenoid Tube Diameter.75 in.19 mm
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque20 - 25 lbf ft27 - 33 Nm
Model Weight (with coil)1.00 lb0,45 kg
Seal kit - CartridgeViton: 990-208-006
Seal and nut kit - CoilViton: 990-770-006Viton: 990-770-006