You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
PVJACAN


$715.40 USD

Tags:

  • SUN HYDRAULICS
  • Material:PVJACAN
  • Model:PVJA-CAN
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PVJACAN (Material Number: PVJACAN) is an externally drained, pilot-operated pressure reducing/relieving valve designed to maintain a consistent reduced pressure at port 1 from a higher primary pressure at inlet port 2. It also features a full-flow relief function from port 1 to tank port 3. This valve is characterized by its insensitivity to pressure at tank port 3, thanks to the pilot section being drained at port 4, which also allows for remote control via pilot or two-way valves. The maximum allowable pressure at port 3 is capped at 3000 psi (210 bar). The valve exhibits low deadband transition between reducing and relieving modes and maintains exceptionally flat pressure-flow characteristics for stability and low hysteresis. The recommended maximum inlet pressure varies based on adjustment ranges, with ranges A, B, and H tested up to a 3000 psi (210 bar) differential, while ranges C and W can handle up to 5000 psi (350 bar) of inlet pressure. This valve incorporates Sun's floating style construction to minimize binding risks due to excessive installation torque or machining variations. It features an internal hex size of 5/32 inches for adjustment screws and a locknut torque range of 80-90 lbf in (9-10 Nm). Cartridges with EPDM seals are suitable for systems using phosphate ester fluids but should not be exposed to petroleum-based products. With a capacity of up to 80 gpm (320 L/min), the PVJACAN model offers reliable performance in hydraulic systems requiring precise pressure control. Its design allows for backflow from port 1 to port 2 under certain conditions while maintaining open status when secondary circuit pressures are below the set threshold.

Externally drained, pilot-operated pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). Draining the pilot section at port 4 makes these valves insensitive to pressure at tank (port 3) and provides a means for remote control by pilot or 2-way valves.

  • Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
  • Pilot operated valves exhibit very low dead-band transition between reducing and relieving modes.
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Pressure on the drain (port 4) is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • By controlling the pressure at the drain (port 4), the effective setting of the valve can be increased over the nominal valve setting.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-24A
Series4
Capacity80 gpm320 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow15 - 20 in³/min.0,25 - 0,33 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 5/8 in.41,3 mm
Valve Installation Torque350 - 375 lbf ft474 - 508 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight3.10 lb1,40 kg
Seal kit - CartridgeViton: 990-024-006

Show FAQ

Additional Resources



Notes:
  • Maximum pressure differentials for spring ranges: A and B are 3000 psi (210 bar) D and E are 2000 psi (140 bar) W is 5000 psi (350 bar) inlet pressure