***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PVHCLDN (PVHCLDN) is an externally drained, pilot-operated pressure reducing-relieving valve designed to maintain a constant reduced pressure at port 1 from a higher primary pressure at inlet port 2, while providing a full-flow relief function from port 1 to tank port 3. This valve is notable for its main stage orifice drilled into the piston, enhancing its durability in physically demanding applications. It features a maximum operating pressure of 5000 psi (350 bar) and is designed with exceptionally flat pressure-flow characteristics, ensuring stability and low hysteresis. The valve's pilot section can be drained at port 4, making it insensitive to tank port 3's pressure and allowing remote control via pilot or two-way valves. The recommended maximum inlet pressure varies by adjustment range, with ranges D, E, N, and Q tested with a 2000 psi (140 bar) differential and ranges A, B, and H tested with a 3000 psi (210 bar) differential. For ranges C and W, an inlet pressure of up to 5000 psi (350 bar) is tested. The valve incorporates Sun's floating style construction to minimize internal part binding due to installation torque or cavity-cartridge machining variations. It provides low deadband transition between reducing and relieving modes but is not fast-acting; for superior dynamic response, direct-acting valves are recommended. Adjustment of the effective setting can be achieved by controlling the drain port's pressure. The PVHCLDN has a capacity of up to 40 gpm (160 L/min), with control pilot flow ranging from 15 to 20 in\u00b3/min (0.25 to 0.33 L/min). Installation requires specific torque values for both the valve body and locknut components.

Externally drained, pilot-operated pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). Draining the pilot section at port 4 makes these valves insensitive to pressure at tank (port 3) and provides a means for remote control by pilot or 2-way valves.

  • These valves have the main stage orifice drilled into the piston rather than a staked-in orifice. This allows the valve to survive physically demanding applications.
  • Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
  • Pilot operated valves exhibit very low dead-band transition between reducing and relieving modes.
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pressure at port 4 should not exceed 5000 psi (350 bar).
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Pressure on the drain (port 4) is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • By controlling the pressure at the drain (port 4), the effective setting of the valve can be increased over the nominal valve setting.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-23A
Series3
Capacity40 gpm160 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow15 - 20 in³/min.0,25 - 0,33 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 1/4 in.31,8 mm
Valve Installation Torque150 - 160 lbf ft203 - 217 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight1.30 lb0,60 kg