***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PVHALHN (PVHALHN) is an externally drained, pilot-operated pressure reducing/relieving valve designed to reduce high primary pressure at the inlet port 2 to a consistent reduced pressure at port 1, with a full-flow relief function from port 1 to tank port 3. This valve is insensitive to pressure at tank port 3 due to its external drainage and allows for remote control via pilot or 2-way valves. The maximum pressure at port 3 should be limited to 3000 psi (210 bar), while the recommended maximum inlet pressure varies based on the adjustment range. The ranges D, E, N, and Q are tested with a maximum differential of 2000 psi (140 bar) between inlet and reduced pressure; ranges A, B, and H allow for a differential of up to 3000 psi (210 bar); ranges C and W can handle an inlet pressure of up to 5000 psi (350 bar). The valve features exceptionally flat pressure-flow characteristics with low hysteresis and is known for its stability. Pressure on drain port 4 directly affects the valve setting at a ratio of 1:1 and should not exceed 5000 psi (350 bar). Additionally, by controlling the drain port's pressure, the effective setting can be increased beyond the nominal value. It incorporates Sun's floating style construction to minimize internal part binding due to excessive installation torque or machining variations. This model has a capacity of up to 40 gpm (160 L/min) and operates effectively within specific torque settings and adjustment parameters. It's important for users requiring superior dynamic response in their systems to consider direct-acting valves as alternatives since pilot-operated valves like this one are not fast-acting by nature.

Externally drained, pilot-operated pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). Draining the pilot section at port 4 makes these valves insensitive to pressure at tank (port 3) and provides a means for remote control by pilot or 2-way valves.

  • Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
  • Pilot operated valves exhibit very low dead-band transition between reducing and relieving modes.
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pressure at port 4 should not exceed 5000 psi (350 bar).
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Pressure on the drain (port 4) is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • By controlling the pressure at the drain (port 4), the effective setting of the valve can be increased over the nominal valve setting.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-23A
Series3
Capacity40 gpm160 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow15 - 20 in³/min.0,25 - 0,33 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 1/4 in.31,8 mm
Valve Installation Torque150 - 160 lbf ft203 - 217 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight1.30 lb0,60 kg