SUN HYDRAULICS
PVHACWN
$357.70 USD
Tags:
- SUN HYDRAULICS
- Material:PVHACWN
- Model:PVHA-CWN
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PVHACWN (PVHACWN) is an externally drained, pilot-operated pressure reducing-relieving valve designed to manage high primary pressures at the inlet port 2 and reduce them to a constant pressure at port 1, while also providing full-flow relief from port 1 to tank port 3. Its design allows for insensitivity to pressure at tank port 3 when the pilot section is drained at port 4, enabling remote control via pilot or two-way valves. The valve can handle a maximum pressure of 3000 psi (210 bar) at port 3 and features a low deadband transition between reducing and relieving modes. It operates with exceptionally flat pressure-flow characteristics and low hysteresis, ensuring stability. The recommended maximum inlet pressure varies by adjustment range, with ranges C and W tested up to 5000 psi (350 bar). Port 4 should not exceed this same pressure limit. The PVHACWN incorporates Sun's floating style construction to minimize internal binding due to installation torque or machining variations. It fits into a T-23A cavity with a Series 3 capacity of up to 40 gpm (160 L/min). The factory settings are established with the control port dead-headed, and it has a maximum operating pressure of 5000 psi (350 bar). Control pilot flow ranges between 15-20 in\u00b3/min (0.25-0.33 L/min), and adjustments can be made via an internal hex screw that increases settings with clockwise turns. This valve is not suited for fast-acting applications; direct acting valves are recommended for superior dynamic response. However, by controlling the drain port pressure, users can increase the effective setting beyond nominal values. Installation involves specific torque requirements: valve installation torque is between 150-160 lbf\u00b7ft (203-217 Nm), while locknut torque is set between 80-90 lbf\u00b7in (9-10 Nm).
The Sun Hydraulics PVHACWN (PVHACWN) is an externally drained, pilot-operated pressure reducing-relieving valve designed to manage high primary pressures at the inlet port 2 and reduce them to a constant pressure at port 1, while also providing full-flow relief from port 1 to tank port 3. Its design allows for insensitivity to pressure at tank port 3 when the pilot section is drained at port 4, enabling remote control via pilot or two-way valves. The valve can handle a maximum pressure of 3000 psi (210 bar) at port 3 and features a low deadband transition between reducing and relieving modes. It operates with exceptionally flat pressure-flow characteristics and low hysteresis, ensuring stability. The recommended maximum inlet pressure varies by adjustment range, with ranges C and W tested up to 5000 psi (350 bar). Port 4 should not exceed this same pressure limit. The PVHACWN incorporates Sun's floating style construction to minimize internal binding due to installation torque or machining variations. It fits into a T-23A cavity with a Series 3 capacity of up to 40 gpm (160 L/min). The factory settings are established with the control port dead-headed, and it has a maximum operating pressure of 5000 psi (350 bar). Control pilot flow ranges between 15-20 in\u00b3/min (0.25-0.33 L/min), and adjustments can be made via an internal hex screw that increases settings with clockwise turns. This valve is not suited for fast-acting applications; direct acting valves are recommended for superior dynamic response. However, by controlling the drain port pressure, users can increase the effective setting beyond nominal values. Installation involves specific torque requirements: valve installation torque is between 150-160 lbf\u00b7ft (203-217 Nm), while locknut torque is set between 80-90 lbf\u00b7in (9-10 Nm).
Externally drained, pilot-operated pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). Draining the pilot section at port 4 makes these valves insensitive to pressure at tank (port 3) and provides a means for remote control by pilot or 2-way valves.
- Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
- Pilot operated valves exhibit very low dead-band transition between reducing and relieving modes.
- Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
- Pressure at port 4 should not exceed 5000 psi (350 bar).
- Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
- Pressure on the drain (port 4) is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
- Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
- By controlling the pressure at the drain (port 4), the effective setting of the valve can be increased over the nominal valve setting.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-23A |
| Series | 3 |
| Capacity | 40 gpm160 L/min. |
| Factory Pressure Settings Established at | blocked control port (dead headed)blocked control port (dead headed) |
| Maximum Operating Pressure | 5000 psi350 bar |
| Control Pilot Flow | 15 - 20 in³/min.0,25 - 0,33 L/min. |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 1 1/4 in.31,8 mm |
| Valve Installation Torque | 150 - 160 lbf ft203 - 217 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | 1.30 lb0,60 kg |
| Seal kit - Cartridge | Viton: 990-023-006 |
Show FAQ
Additional Resources
- Sun Expands Corrosion-Resistant Solutions
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Reducing and Reducing/Relieving Valves
- Manufacturing Sun Cartridge Cavities
- Fluid and Temperature Recommendations
- Performance Data
- Sun's Floating Style Screw-In Cartridge
- Units of Measure, Settings, and Conversions
- Sun Model Code Explanation; 999-901-334
- Cavity Information (S-171) and Tooling
- Cartridges: Materials of Construction
Notes:
- Maximum pressure differentials for spring ranges: A and B are 3000 psi (210 bar) D and E are 2000 psi (140 bar) W is 5000 psi (350 bar) inlet pressure