***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PVFALAN (PVFALAN) is an externally drained, pilot-operated pressure reducing-relieving valve designed to manage high primary pressure at the inlet port 2, reducing it to a consistent and lower pressure at port 1. It also provides a full-flow relief function from port 1 to tank port 3. The valve's design includes a pilot section that drains at port 4, making it insensitive to pressure changes at tank port 3 and allowing for remote control via pilot or two-way valves. This feature enhances its versatility in various hydraulic systems. The maximum allowable pressure at port 3 is capped at 3000 psi (210 bar), while the recommended maximum inlet pressure varies by adjustment range: D, E, N, and Q are tested with a maximum differential of 2000 psi (140 bar), whereas ranges A, B, and H can handle up to a differential of 3000 psi (210 bar). Ranges C and W are tested with an inlet pressure of up to 5000 psi (350 bar). Notably, the valve exhibits low deadband transition between reducing and relieving modes and maintains exceptionally flat pressure-flow characteristics with high stability and low hysteresis. The valve's effective setting can be adjusted by controlling the drain port's pressure, which should not exceed 5000 psi (350 bar). The PVFALAN employs Sun's floating style construction to minimize internal binding due to excessive torque or machining variations during installation. With a capacity of up to 20 gpm (80 L/min) and factory settings established under blocked control conditions, this valve offers reliable performance in demanding applications requiring precise pressure regulation.

Externally drained, pilot-operated pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). Draining the pilot section at port 4 makes these valves insensitive to pressure at tank (port 3) and provides a means for remote control by pilot or 2-way valves.

  • Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
  • Pilot operated valves exhibit very low dead-band transition between reducing and relieving modes.
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pressure at port 4 should not exceed 5000 psi (350 bar).
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • Pressure on the drain (port 4) is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
  • W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
  • By controlling the pressure at the drain (port 4), the effective setting of the valve can be increased over the nominal valve setting.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-22A
Series2
Capacity20 gpm80 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow10 - 15 in³/min.0,16 - 0,25 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 1/8 in.28,6 mm
Valve Installation Torque45 - 50 lbf ft61 - 68 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.60 lb0,30 kg