***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PVDDLNN (PVDDLNN) is a ventable, pilot-operated pressure reducing-relieving valve designed to maintain a constant reduced pressure at port 1 from a higher primary pressure at the inlet, featuring a full-flow relief function from port 1 to tank port 3. This valve includes a vent port (port 4) for remote control via pilot or two-way valves. Unlike conventional designs, this model has the main stage orifice drilled into the piston, enhancing durability in demanding applications. The valve setting can be directly influenced by the pressure at port 3 on a 1:1 ratio and should not surpass 3000 psi (210 bar). If reverse free flow is needed in the circuit, adding an external check valve is advisable as reverse flow from reduced pressure port 1 to inlet port 2 may close the main spool. The PVDDLNN exhibits low deadband transition between reducing and relieving modes, with maximum inlet pressures varying by adjustment range: D, E, N, and Q allow for a maximum differential of 2000 psi (140 bar), while ranges A, B, and H permit up to 3000 psi (210 bar), and C and W are tested with up to 5000 psi (350 bar). Its design ensures exceptionally flat pressure-flow characteristics with high stability and low hysteresis. The effective setting can be controlled below nominal by managing the vent port's pressure. It incorporates Sun's floating style construction to minimize internal binding due to excessive installation torque or cavity/cartridge machining variations. The valve fits within Cavity T-21A Series 1 with a capacity of up to 10 gpm (40 L/min), features an internal hex adjustment screw size of 5/32 in., and has specific torque requirements for installation and locknut adjustments.

Ventable, pilot-operated pressure reducing/relieving valves reduce a high primary pressure at the inlet to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). The vent port (port 4) can be used as a means for remote control by pilot or 2-way valves.

  • These valves have the main stage orifice drilled into the piston rather than a staked-in orifice. This allows the valve to survive physically demanding applications.
  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • Pilot operated valves exhibit very low dead-band transition between reducing and relieving modes.
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • By controlling the pressure at the vent (port 4), the effective setting of the valve can be controlled below the nominal valve setting.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-21A
Series1
Capacity10 gpm40 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow7 - 10 in³/min.0,11 - 0,16 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.30 lb0,15 kg
Seal kit - CartridgeViton: 990-021-006