SUN HYDRAULICS
PVDBLWV
$126.60 USD
Tags:
- SUN HYDRAULICS
- Material:PVDBLWV
- Model:PVDB-LWV
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PVDBLWV (PVDBLWV) is a ventable, pilot-operated pressure reducing/relieving valve designed to maintain a constant reduced pressure at port 1 by reducing a higher primary pressure at the inlet, while offering a full-flow relief function from port 1 to tank port 3. The vent port, port 4, facilitates remote control via pilot or 2-way valves. The valve can handle pressures at port 3 that are directly additive to the valve setting at a 1:1 ratio, with an upper limit of 3000 psi (210 bar). It is critical to note that full reverse flow from reduced pressure port 1 back to inlet port 2 may cause the main spool to close; thus, adding a separate check valve is advisable if reverse free flow is required. This model exhibits low deadband transition between reducing and relieving modes and maintains stable performance due to its exceptionally flat pressure-flow characteristics and low hysteresis. The recommended maximum inlet pressure varies by adjustment range, with ranges D, E, N, and Q tested at a maximum differential of 2000 psi (140 bar), while ranges A, B, and H are tested with up to 3000 psi (210 bar). Ranges C and W accommodate up to 5000 psi (350 bar) of inlet pressure. The effective setting of the valve can be adjusted below its nominal setting by controlling the pressure at vent port 4. Incorporating Sun's floating style construction minimizes internal part binding due to excessive installation torque or machining variations. With a capacity of up to 10 gpm (40 L/min), this model features factory pressure settings established under blocked control conditions and operates efficiently within its specified parameters.
The Sun Hydraulics PVDBLWV (PVDBLWV) is a ventable, pilot-operated pressure reducing/relieving valve designed to maintain a constant reduced pressure at port 1 by reducing a higher primary pressure at the inlet, while offering a full-flow relief function from port 1 to tank port 3. The vent port, port 4, facilitates remote control via pilot or 2-way valves. The valve can handle pressures at port 3 that are directly additive to the valve setting at a 1:1 ratio, with an upper limit of 3000 psi (210 bar). It is critical to note that full reverse flow from reduced pressure port 1 back to inlet port 2 may cause the main spool to close; thus, adding a separate check valve is advisable if reverse free flow is required. This model exhibits low deadband transition between reducing and relieving modes and maintains stable performance due to its exceptionally flat pressure-flow characteristics and low hysteresis. The recommended maximum inlet pressure varies by adjustment range, with ranges D, E, N, and Q tested at a maximum differential of 2000 psi (140 bar), while ranges A, B, and H are tested with up to 3000 psi (210 bar). Ranges C and W accommodate up to 5000 psi (350 bar) of inlet pressure. The effective setting of the valve can be adjusted below its nominal setting by controlling the pressure at vent port 4. Incorporating Sun's floating style construction minimizes internal part binding due to excessive installation torque or machining variations. With a capacity of up to 10 gpm (40 L/min), this model features factory pressure settings established under blocked control conditions and operates efficiently within its specified parameters.
Ventable, pilot-operated pressure reducing/relieving valves reduce a high primary pressure at the inlet to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). The vent port (port 4) can be used as a means for remote control by pilot or 2-way valves.
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- Pilot operated valves exhibit very low dead-band transition between reducing and relieving modes.
- Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
- Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
- By controlling the pressure at the vent (port 4), the effective setting of the valve can be controlled below the nominal valve setting.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-21A |
| Series | 1 |
| Capacity | 10 gpm40 L/min. |
| Factory Pressure Settings Established at | blocked control port (dead headed)blocked control port (dead headed) |
| Maximum Operating Pressure | 5000 psi350 bar |
| Control Pilot Flow | 7 - 10 in³/min.0,11 - 0,16 L/min. |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .30 lb0,15 kg |
| Seal kit - Cartridge | Viton: 990-021-006 |
Show FAQ
Additional Resources
- Sun Expands Corrosion-Resistant Solutions
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Reducing and Reducing/Relieving Valves
- Manufacturing Sun Cartridge Cavities
- Fluid and Temperature Recommendations
- Performance Data
- Sun's Floating Style Screw-In Cartridge
- Units of Measure, Settings, and Conversions
- Sun Model Code Explanation; 999-901-334
- Cavity Information (S-171) and Tooling
- Cartridges: Materials of Construction
Notes:
- Maximum pressure differentials for spring ranges: A and B are 3000 psi (210 bar) D and E are 2000 psi (140 bar) W is 5000 psi (350 bar) inlet pressure