***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PVDBCWV (PVDBCWV) is a ventable, pilot-operated pressure reducing/relieving valve designed to reduce high primary pressure at the inlet to a constant reduced pressure at port 1, while providing a full-flow relief function from port 1 to tank port 3. This valve features a vent port at port 4, allowing for remote control via pilot or two-way valves. The pressure at port 3 can be directly added to the valve setting in a 1:1 ratio, with an upper limit of 3000 psi (210 bar). It is important to note that full reverse flow from reduced pressure port 1 to inlet port 2 may cause the main spool to close; thus, if reverse free flow is needed, adding a separate check valve is recommended. The PVDBCWV model exhibits minimal deadband transition between reducing and relieving modes and maintains exceptionally flat pressure-flow characteristics. It offers stability and low hysteresis due to its pilot-operated design. The maximum recommended inlet pressure varies by adjustment range: Ranges D, E, N, and Q support up to a 2000 psi (140 bar) differential; Ranges A, B, and H support up to 3000 psi (210 bar); Ranges C and W handle up to 5000 psi (350 bar). By adjusting the vent port pressure, users can control the effective setting of the valve below its nominal setting. This model incorporates Sun's floating style construction to minimize internal part binding from excessive torque or machining variations. It fits into cavity T-21A with a capacity of 10 gpm (40 L/min). The factory establishes pressure settings with blocked control ports dead-headed. Maximum operating pressure reaches up to 5000 psi (350 bar), with control pilot flow between 7-10 in\u00b3/min (0.11-0.16 L/min). The installation torque ranges between 30-35 lbf ft (41-47 Nm), with an adjustment screw internal hex size of 5/32 in.

Ventable, pilot-operated pressure reducing/relieving valves reduce a high primary pressure at the inlet to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). The vent port (port 4) can be used as a means for remote control by pilot or 2-way valves.

  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • Pilot operated valves exhibit very low dead-band transition between reducing and relieving modes.
  • Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
  • Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
  • By controlling the pressure at the vent (port 4), the effective setting of the valve can be controlled below the nominal valve setting.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-21A
Series1
Capacity10 gpm40 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Control Pilot Flow7 - 10 in³/min.0,11 - 0,16 L/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.30 lb0,15 kg
Seal kit - CartridgeViton: 990-021-006

Show FAQ

Additional Resources



Notes:
  • Maximum pressure differentials for spring ranges: A and B are 3000 psi (210 bar) D and E are 2000 psi (140 bar) W is 5000 psi (350 bar) inlet pressure