***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PVDAWDV (Material Number: PVDAWDV) is an externally drained, pilot-operated pressure reducing/relieving valve designed to reduce a high primary pressure at the inlet port 2 to a constant reduced pressure at port 1. It also provides a full-flow relief function from port 1 to tank port 3. The valve's design includes draining the pilot section at port 4, making it insensitive to pressure at tank port 3 and allowing for remote control via pilot or two-way valves. Maximum pressure at port 3 is limited to 3000 psi (210 bar), and the recommended maximum inlet pressure varies by adjustment range, with ranges C and W tested up to an inlet pressure of 5000 psi (350 bar). The valve exhibits low deadband transition between reducing and relieving modes, exceptionally flat pressure-flow characteristics, stability, and low hysteresis. Pressure on drain port 4 should not exceed 5000 psi (350 bar) as it directly affects the valve setting at a 1:1 ratio. The PVDAWDV is not fast-acting; for superior dynamic response, direct-acting valves are recommended. The W and Y controls offer adjustable settings across their full range unless specified otherwise. If reverse free flow is required in the circuit, a separate check valve should be considered as reverse flow from reduced pressure port 1 to inlet port 2 may cause the main spool to close. This model incorporates Sun's floating style construction to minimize potential binding of internal parts due to excessive installation torque or machining variations in cavity/cartridge applications. The valve has a cavity type T-21A with a series capacity of 10 gpm (40 L/min) and can be adjusted using its internal hex size screw with specified torque settings for secure installation.
The Sun Hydraulics PVDAWDV (Material Number: PVDAWDV) is an externally drained, pilot-operated pressure reducing/relieving valve designed to reduce a high primary pressure at the inlet port 2 to a constant reduced pressure at port 1. It also provides a full-flow relief function from port 1 to tank port 3. The valve's design includes draining the pilot section at port 4, making it insensitive to pressure at tank port 3 and allowing for remote control via pilot or two-way valves. Maximum pressure at port 3 is limited to 3000 psi (210 bar), and the recommended maximum inlet pressure varies by adjustment range, with ranges C and W tested up to an inlet pressure of 5000 psi (350 bar). The valve exhibits low deadband transition between reducing and relieving modes, exceptionally flat pressure-flow characteristics, stability, and low hysteresis. Pressure on drain port 4 should not exceed 5000 psi (350 bar) as it directly affects the valve setting at a 1:1 ratio. The PVDAWDV is not fast-acting; for superior dynamic response, direct-acting valves are recommended. The W and Y controls offer adjustable settings across their full range unless specified otherwise. If reverse free flow is required in the circuit, a separate check valve should be considered as reverse flow from reduced pressure port 1 to inlet port 2 may cause the main spool to close. This model incorporates Sun's floating style construction to minimize potential binding of internal parts due to excessive installation torque or machining variations in cavity/cartridge applications. The valve has a cavity type T-21A with a series capacity of 10 gpm (40 L/min) and can be adjusted using its internal hex size screw with specified torque settings for secure installation.
Externally drained, pilot-operated pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). Draining the pilot section at port 4 makes these valves insensitive to pressure at tank (port 3) and provides a means for remote control by pilot or 2-way valves.
- Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
- Pilot operated valves exhibit very low dead-band transition between reducing and relieving modes.
- Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C and W are tested with 5000 psi (350 bar) of inlet pressure.
- Pressure at port 4 should not exceed 5000 psi (350 bar).
- Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
- Pressure on the drain (port 4) is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
- Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
- W and Y controls (where applicable) can be specified with or without a special setting. When no special setting is specified, the valve is adjustable throughout its full range using the W or Y control. When a special setting is specified, this setting represents the maximum setting of the valve.
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- By controlling the pressure at the drain (port 4), the effective setting of the valve can be increased over the nominal valve setting.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-21A |
| Series | 1 |
| Capacity | 10 gpm40 L/min. |
| Factory Pressure Settings Established at | blocked control port (dead headed)blocked control port (dead headed) |
| Maximum Operating Pressure | 5000 psi350 bar |
| Control Pilot Flow | 7 - 10 in³/min.0,11 - 0,16 L/min. |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | .30 lb0,15 kg |
| Seal kit - Cartridge | Viton: 990-021-006 |
Show FAQ
Additional Resources
- Sun Expands Corrosion-Resistant Solutions
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Reducing and Reducing/Relieving Valves
- Manufacturing Sun Cartridge Cavities
- Fluid and Temperature Recommendations
- Performance Data
- Sun's Floating Style Screw-In Cartridge
- Units of Measure, Settings, and Conversions
- Sun Model Code Explanation; 999-901-334
- Cavity Information (S-171) and Tooling
- Cartridges: Materials of Construction
Notes:
- Maximum pressure differentials for spring ranges: A and B are 3000 psi (210 bar) D and E are 2000 psi (140 bar) W is 5000 psi (350 bar) inlet pressure