SUN HYDRAULICS
PSFTXFV
$201.20 USD
Tags:
- SUN HYDRAULICS
- Material:PSFTXFV
- Model:PSFT-XFV
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PSFTXFV (PSFTXFV) is a direct-acting reducer-reliever valve designed to interface between a low-flow pressure source at port 4 and a circuit with higher flow requirements. It effectively reduces high primary pressure at inlet port 2 to a lower pressure at port 1, while also providing full-flow relief from port 1 to tank port 3. The valve's damped construction ensures stable operation, making it suitable for high reduced pressures. It is biased to the relieving mode with a 100 psi (7 bar) spring, and any pressure at port 4 directly adds to the valve's setting once the threshold is surpassed. The maximum pressure allowed at port 3 is limited to 3000 psi (210 bar), and all spring ranges are tested under a maximum inlet pressure of 5000 psi (350 bar). This valve is particularly suitable for accumulator circuits due to its reduced secondary circuit leakage stemming from the absence of pilot control flow. Its direct-acting design offers highly reliable operation in contaminated systems, especially under dead-headed conditions, and provides superior dynamic response compared to pilot-operated models. The valve's drain port pressure adds directly to the setting at a 1:1 ratio and should not exceed 5000 psi (350 bar). Leakage from port 3 is proportional to the pressure differential and inversely proportional to viscosity. For reverse flow requirements from reduced pressure port 1 to inlet port 2, an additional check valve may be necessary as reverse flow can cause the main spool to close. The PSFTXFV incorporates Sun's floating style construction, minimizing internal part binding risks due to excessive installation torque or cavity/cartridge machining variations. With a cavity T-22A Series capacity of up to 20 gpm (80 L/min), this model ensures efficient performance in relevant hydraulic applications.
The Sun Hydraulics PSFTXFV (PSFTXFV) is a direct-acting reducer-reliever valve designed to interface between a low-flow pressure source at port 4 and a circuit with higher flow requirements. It effectively reduces high primary pressure at inlet port 2 to a lower pressure at port 1, while also providing full-flow relief from port 1 to tank port 3. The valve's damped construction ensures stable operation, making it suitable for high reduced pressures. It is biased to the relieving mode with a 100 psi (7 bar) spring, and any pressure at port 4 directly adds to the valve's setting once the threshold is surpassed. The maximum pressure allowed at port 3 is limited to 3000 psi (210 bar), and all spring ranges are tested under a maximum inlet pressure of 5000 psi (350 bar). This valve is particularly suitable for accumulator circuits due to its reduced secondary circuit leakage stemming from the absence of pilot control flow. Its direct-acting design offers highly reliable operation in contaminated systems, especially under dead-headed conditions, and provides superior dynamic response compared to pilot-operated models. The valve's drain port pressure adds directly to the setting at a 1:1 ratio and should not exceed 5000 psi (350 bar). Leakage from port 3 is proportional to the pressure differential and inversely proportional to viscosity. For reverse flow requirements from reduced pressure port 1 to inlet port 2, an additional check valve may be necessary as reverse flow can cause the main spool to close. The PSFTXFV incorporates Sun's floating style construction, minimizing internal part binding risks due to excessive installation torque or cavity/cartridge machining variations. With a cavity T-22A Series capacity of up to 20 gpm (80 L/min), this model ensures efficient performance in relevant hydraulic applications.
The direct-acting reducer/reliever main section is meant to act as an interface between a low flow pressure source at port 4 and a circuit with higher flow requirements. The valve will reduce a high primary pressure at the inlet (port 2) to a reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). The valve incorporates a damped construction for stable operation allowing the use of high reduced pressure.
- The valve is biased to the relieving mode with a 100 psi (7 bar) spring. Pressure at port 4 is directly added to the setting of the valve once this threshold is exceeded. For example, 1000 psi (70 bar) at port 4 will result in a setting of 900 psi (63 bar) at port 1.
- Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
- All spring ranges are tested for correct operation with 5000 psi (350 bar) inlet pressure.
- Suitable for accumulator circuits since the absence of pilot control flow results in reduced secondary circuit leakage.
- Direct acting concept provides highly reliable operation in contaminated systems, especially at dead headed conditions.
- Direct operated version offers superior dynamic response compared to equivalent pilot operated models.
- Pressure on the drain (port 4) is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
- Leakage specified in Technical Data is out of port 3 with a supply pressure of 2000 psi (140 bar) and the valve set at mid range. This leakage is directly proportional to pressure differential and inversely proportional to viscosity expressed in centistokes.
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-22A |
| Series | 2 |
| Capacity | 20 gpm80 L/min. |
| Factory Pressure Settings Established at | blocked control port (dead headed)blocked control port (dead headed) |
| Maximum Operating Pressure | 5000 psi350 bar |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 3 in³/min.@1000 psi50 cc/min.@70 bar |
| Valve Hex Size | 1 1/8 in.28,6 mm |
| Valve Installation Torque | 45 - 50 lbf ft61 - 68 Nm |
| Model Weight | .30 lb0,15 kg |
| Seal kit - Cartridge | Viton: 990-022-006 |
Show FAQ
Additional Resources
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Sun Expands Corrosion-Resistant Solutions
- Manufacturing Sun Cartridge Cavities
- Reducing and Reducing/Relieving Valves
- Performance Data
- Sun's Floating Style Screw-In Cartridge
- Units of Measure, Settings, and Conversions
- Sun Model Code Explanation; 999-901-334
- Cavity Information (S-171) and Tooling
- Cartridges: Materials of Construction
- Fluid and Temperature Recommendations