You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
PSFBLAN


$140.30 USD

Tags:

  • SUN HYDRAULICS
  • Material:PSFBLAN
  • Model:PSFB-LAN
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PSFBLAN (PSFBLAN) is a direct-acting, pressure reducing/relieving valve designed to efficiently manage hydraulic pressure systems. This valve reduces a high primary pressure at the inlet port (port 2) to a consistent, reduced pressure at port 1 while offering a full-flow relief function from port 1 to tank port 3. The inclusion of draining port 4 ensures the valve remains unaffected by pressure at port 3, enhancing its reliability in various applications. Engineered with a damped construction, this valve provides stable operation even under high reduced pressures. It is particularly suitable for accumulator circuits due to its design, which minimizes secondary circuit leakage by eliminating pilot control flow. The direct-acting mechanism offers robust performance in contaminated systems and is especially effective under dead-headed conditions. The PSFBLAN model features a unique transitional step between reducing and relieving modes that equals five percent of the high end of the adjustment range, making it unsuitable for counterbalancing applications but advantageous for other uses requiring dynamic response. The maximum allowable pressure on the drain port 4 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar). This model also supports reverse flow from reduced pressure port 1 to inlet port 2; however, additional check valves are recommended for circuits requiring free reverse flow. Key specifications include a maximum operating pressure of 5000 psi (350 bar), capacity of up to 20 gpm (80 L/min), and factory pressure settings established with blocked control ports. The valve's installation torque ranges between 45-50 lbf ft (61-68 Nm), ensuring secure placement in hydraulic systems. With its floating style construction, this Sun Hydraulics valve minimizes internal binding risks due to installation or machining variations, making it an ideal choice for stable and reliable hydraulic system operations.

Direct-acting, pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). Draining port 4 makes the valve insensitive to pressure at port 3. These valves incorporate a damped construction for stable operation allowing the use of high reduced pressure.

  • Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
  • All spring ranges are tested for correct operation with 5000 psi (350 bar) inlet pressure.
  • Suitable for accumulator circuits since the absence of pilot control flow results in reduced secondary circuit leakage.
  • Direct acting concept provides highly reliable operation in contaminated systems, especially at dead headed conditions.
  • Unlike pilot operated versions, direct acting valves exhibit a transitional step between reducing and relieving modes. This step equals 5% of the high end of the adjustment range, independent of the valve setting. Therefore, these valves may not be suitable for counterbalancing applications.
  • Direct operated version offers superior dynamic response compared to equivalent pilot operated models.
  • Pressure on the drain (port 4) is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Leakage specified in Technical Data is out of port 3 with a supply pressure of 2000 psi (140 bar) and the valve set at mid range. This leakage is directly proportional to pressure differential and inversely proportional to viscosity expressed in centistokes.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • By controlling the pressure at the drain (port 4), the effective setting of the valve can be increased over the nominal valve setting.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-22A
Series2
Capacity20 gpm80 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Maximum Valve Leakage at 110 SUS (24 cSt)3 in³/min.@1000 psi50 cc/min.@70 bar
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 1/8 in.28,6 mm
Valve Installation Torque45 - 50 lbf ft61 - 68 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.30 lb0,15 kg
Seal kit - CartridgeViton: 990-022-006

Show FAQ

Additional Resources