You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
PSDPLEN2D24A


$574.20 USD

Tags:

  • SUN HYDRAULICS
  • Material:PSDPLEN2D24A
  • Model:PSDP-LEN@2D24A
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PSDPLEN2D24A (Material Number: PSDPLEN2D24A) is an electroproportional, direct-acting reducer-reliever valve designed to manage high primary pressure at the inlet port 2, reducing it to a constant pressure at port 1, while providing a full flow relief function from port 1 to tank port 3. The valve is inherently set to the relieving mode and is activated by energizing the coil, which connects port 2 to port 1. The pressure at port 1 increases proportionally with the current supplied to the coil. If the pressure at port 1 surpasses the coil-induced setting, it is relieved to port 3. Port 4 draining ensures insensitivity to pressure changes at port 3. The transition between reducing and relieving modes is closed, ensuring minimal oil consumption and leakage. This valve supports manual control options for emergency settings or boosting during power failures. The maximum allowable pressure at port 3 is limited to 3000 psi (210 bar), with all spring ranges tested up to an inlet pressure of 5000 psi (350 bar). It is suitable for accumulator circuits due to reduced secondary circuit leakage from its direct-acting design, which also enhances reliability in contaminated systems. Leakage rates are specified based on technical data parameters, directly proportional to pressure differential and inversely proportional to viscosity in centistokes. For optimal performance, use an amplifier with adjustable dither between 100-250 Hz. The valve supports reverse flow from reduced pressure port 1 back to inlet port 2; however, a separate check valve may be needed if reverse free flow is required in your circuit setup. Additionally, controlling drain port pressure can increase effective valve settings beyond nominal levels. Installation requires specific torque values and dimensions detailed in product specifications for proper assembly and operation.

This electro-proportional, direct-acting reducer/reliever valve reduces a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full flow relief function from port 1 to tank (port 3). The valve is biased to the relieving mode. Energizing the coil connects port 2 to port 1. Increasing the current to the coil will proportionally increase the reduced pressure at port 1. If pressure at port 1 exceeds the setting induced by the coil, pressure at port 1 is relieved to port 3. Draining port 4 makes the valve insensitive to pressure at port 3. This valve is closed in the transition between reducing and relieving resulting in very low consumption of oil. Optional full manual control is available.

  • Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
  • All spring ranges are tested for correct operation with 5000 psi (350 bar) inlet pressure.
  • Suitable for accumulator circuits since the absence of pilot control flow results in reduced secondary circuit leakage.
  • Direct acting concept provides highly reliable operation in contaminated systems, especially at dead headed conditions.
  • Leakage specified in Technical Data is out of port 3 with a supply pressure of 2000 psi (140 bar) and the valve set at mid range. This leakage is directly proportional to pressure differential and inversely proportional to viscosity expressed in centistokes.
  • The transition from reducing to relieving is closed. The result is very low leakage. However, there is a transitional step increase in pressure between reducing and relieving modes. This step equals about 5% of the high end of the adjustment range, independent of the valve setting.
  • For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • Uses for the 'L' manual screw adjustment include: emergency valve setting during power failure or alternatively boosting the valve setting
  • With the 'L' adjustment screw, all ranges are factory set at zero (adjustment screw fully backed out). With the coil de-energized, clockwise adjustment of the screw will increase the spring bias load up to the maximum setting for that range. With the coil energized, any mechanical pressure setting is directly additive to the coil induced value.
  • By controlling the pressure at the drain (port 4), the effective setting of the valve can be increased over the nominal valve setting.
  • Pressure on the drain (port 4) is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-21A
Series1
Capacity5 gpm20 L/min.
Maximum Operating Pressure5000 psi350 bar
Maximum Valve Leakage at 110 SUS (24 cSt)2.5 in³/min.41 cc/min.
Optimum Inlet Pressure3000 psi210 bar
Adjustment - Number of Clockwise Turns to Increase Setting55
Solenoid Tube Diameter.75 in.19 mm
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight (with coil)1.20 lb0,55 kg
Seal kit - CartridgeViton: 990-021-006
Seal and nut kit - CoilViton: 990-770-006Viton: 990-770-006

Show FAQ

Additional Resources



Notes:
  • Please verify cartridge clearance requirements when choosing a Sun manifold. Different valve controls and coils require different clearances.