You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
PSDBOEV


$137.00 USD

Tags:

  • SUN HYDRAULICS
  • Material:PSDBOEV
  • Model:PSDB-OEV
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PSDBOEV (PSDBOEV) is a direct-acting, pressure-reducing/relieving valve designed to manage high primary pressures by reducing them to a constant pressure at port 1 while offering a full-flow relief function from port 1 to tank port 3. It features a damped construction for stable operation, making it suitable for applications requiring high reduced pressure. The valve is particularly effective in accumulator circuits due to its lack of pilot control flow, which minimizes secondary circuit leakage. Its direct-acting design ensures reliable performance even in contaminated systems and under dead-headed conditions. However, the transitional step between reducing and relieving modes may not make it ideal for counterbalancing applications. The maximum pressure at port 3 is limited to 3000 psi (210 bar), and all spring ranges are tested with an inlet pressure of 5000 psi (350 bar). Pressure on drain port 4 directly affects the valve setting at a ratio of 1:1, with a maximum allowable pressure of 5000 psi (350 bar). The valve's leakage rate is specified as being proportional to the pressure differential and inversely proportional to viscosity. Full reverse flow from reduced pressure port 1 to inlet port 2 can cause the main spool to close, necessitating an additional check valve if reverse free flow is required. The PSDBOEV incorporates Sun's floating style construction, which helps prevent internal part binding due to installation torque or machining variations. It has a capacity of up to 10 gpm (40 L/min) and comes with specific installation and adjustment parameters for optimal performance.

Direct-acting, pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). Draining port 4 makes the valve insensitive to pressure at port 3. These valves incorporate a damped construction for stable operation allowing the use of high reduced pressure.

  • Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
  • All spring ranges are tested for correct operation with 5000 psi (350 bar) inlet pressure.
  • Suitable for accumulator circuits since the absence of pilot control flow results in reduced secondary circuit leakage.
  • Direct acting concept provides highly reliable operation in contaminated systems, especially at dead headed conditions.
  • Unlike pilot operated versions, direct acting valves exhibit a transitional step between reducing and relieving modes. This step equals 5% of the high end of the adjustment range, independent of the valve setting. Therefore, these valves may not be suitable for counterbalancing applications.
  • Direct operated version offers superior dynamic response compared to equivalent pilot operated models.
  • Pressure on the drain (port 4) is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
  • Leakage specified in Technical Data is out of port 3 with a supply pressure of 2000 psi (140 bar) and the valve set at mid range. This leakage is directly proportional to pressure differential and inversely proportional to viscosity expressed in centistokes.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • By controlling the pressure at the drain (port 4), the effective setting of the valve can be increased over the nominal valve setting.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-21A
Series1
Capacity10 gpm40 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Maximum Valve Leakage at 110 SUS (24 cSt)2 in³/min.@1000 psi30 cc/min.@70 bar
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight.30 lb0,15 kg
Seal kit - CartridgeViton: 990-021-006

Show FAQ

Additional Resources



Notes:
  • For Series 1 cartridges configured with an O control (panel mount handknob), a .75 in. (19 mm) diameter hole is required in the panel.