***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PRJBLBV (PRJBLBV) is a direct-acting pressure reducing/relieving valve designed to reduce a high primary pressure at inlet port 2 to a constant reduced pressure at port 1, while providing full-flow relief from port 1 to tank port 3. This valve features a damped construction for stable operation, making it suitable for use with high reduced pressures. Pressure at port 3 adds directly to the valve setting in a 1:1 ratio and should not exceed 3000 psi (210 bar). The leakage specified occurs out of port 3 with a supply pressure of 2000 psi (140 bar) and is directly proportional to pressure differential and inversely proportional to viscosity. All three-port cartridges are interchangeable, sharing the same flow path and cavity size for a given frame. It is recommended that full capacity return line port 3 be used with reducing/relieving cartridges if considering mounting configurations. To accommodate reverse free flow from the reduced pressure port back to the inlet, adding a separate check valve may be necessary. This model is highly reliable in contaminated systems due to its direct-acting concept, which provides superior dynamic response compared to pilot-operated versions. It incorporates Sun's floating style construction to minimize binding of internal parts due to excessive installation torque or machining variations in the cavity/cartridge. The PRJBLBV model has an adjustment range that allows for five clockwise turns to increase setting, with maximum operating pressures up to 5000 psi (350 bar). It includes features like factory pressure settings established at blocked control ports and suitability for accumulator circuits due to reduced secondary circuit leakage.
The Sun Hydraulics PRJBLBV (PRJBLBV) is a direct-acting pressure reducing/relieving valve designed to reduce a high primary pressure at inlet port 2 to a constant reduced pressure at port 1, while providing full-flow relief from port 1 to tank port 3. This valve features a damped construction for stable operation, making it suitable for use with high reduced pressures. Pressure at port 3 adds directly to the valve setting in a 1:1 ratio and should not exceed 3000 psi (210 bar). The leakage specified occurs out of port 3 with a supply pressure of 2000 psi (140 bar) and is directly proportional to pressure differential and inversely proportional to viscosity. All three-port cartridges are interchangeable, sharing the same flow path and cavity size for a given frame. It is recommended that full capacity return line port 3 be used with reducing/relieving cartridges if considering mounting configurations. To accommodate reverse free flow from the reduced pressure port back to the inlet, adding a separate check valve may be necessary. This model is highly reliable in contaminated systems due to its direct-acting concept, which provides superior dynamic response compared to pilot-operated versions. It incorporates Sun's floating style construction to minimize binding of internal parts due to excessive installation torque or machining variations in the cavity/cartridge. The PRJBLBV model has an adjustment range that allows for five clockwise turns to increase setting, with maximum operating pressures up to 5000 psi (350 bar). It includes features like factory pressure settings established at blocked control ports and suitability for accumulator circuits due to reduced secondary circuit leakage.
Direct-acting, pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). These valves incorporate a damped construction for stable operation allowing the use of high reduced pressure.
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
- Leakage specified in Technical Data is out of port 3 with a supply pressure of 2000 psi (140 bar) and the valve set at mid range. This leakage is directly proportional to pressure differential and inversely proportional to viscosity expressed in centistokes.
- All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- All spring ranges are tested for correct operation with 5000 psi (350 bar) inlet pressure.
- Suitable for accumulator circuits since the absence of pilot control flow results in reduced secondary circuit leakage.
- Direct acting concept provides highly reliable operation in contaminated systems, especially at dead headed conditions.
- Unlike pilot operated versions, direct acting valves exhibit a transitional step between reducing and relieving modes. This step equals 5% of the high end of the adjustment range, independent of the valve setting. Therefore, these valves may not be suitable for counterbalancing applications.
- Direct operated version offers superior dynamic response compared to equivalent pilot operated models.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-19A |
| Series | 4 |
| Capacity | 80 gpm320 L/min. |
| Factory Pressure Settings Established at | blocked control port (dead headed)blocked control port (dead headed) |
| Maximum Operating Pressure | 5000 psi350 bar |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 5 in³/min.80 cc/min. |
| Adjustment - Number of Clockwise Turns to Increase Setting | 55 |
| Valve Hex Size | 1 5/8 in.41,3 mm |
| Valve Installation Torque | 350 - 375 lbf ft474 - 508 Nm |
| Adjustment Screw Internal Hex Size | 5/32 in.4 mm |
| Locknut Hex Size | 9/16 in.15 mm |
| Locknut Torque | 80 - 90 lbf in.9 - 10 Nm |
| Model Weight | 3.10 lb1,40 kg |
| Seal kit - Cartridge | Viton: 990-019-006 |
Show FAQ
Additional Resources
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Cartridges with EPDM Seals
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Sun Expands Corrosion-Resistant Solutions
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- Manufacturing Sun Cartridge Cavities
- Reducing and Reducing/Relieving Valves
- Sun's Floating Style Screw-In Cartridge
- Units of Measure, Settings, and Conversions
- Sun Model Code Explanation; 999-901-334
- Cavity Information (S-171) and Tooling
- Cartridges: Materials of Construction
- Fluid and Temperature Recommendations
- Performance Data