You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
PRHBCBN


$271.70 USD

Tags:

  • SUN HYDRAULICS
  • Material:PRHBCBN
  • Model:PRHB-CBN
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PRHBCBN (PRHBCBN) is a high-performance, direct-acting pressure reducing/relieving valve designed to manage hydraulic system pressures effectively. This valve reduces a high primary pressure at inlet port 2 to a consistent, reduced pressure at port 1, while also providing full-flow relief from port 1 to tank port 3. Its damped construction ensures stable operation even when utilizing high reduced pressures, making it suitable for systems requiring precise pressure control. The valve's design incorporates a floating style construction to minimize the risk of internal parts binding due to installation torque or machining variations. With a maximum operating pressure of 5000 psi (350 bar) and a capacity of up to 40 gpm (160 L/min), this valve is well-suited for demanding applications. It features EPDM seals for compatibility with phosphate ester fluids, although exposure to petroleum-based fluids should be avoided as it can damage the seals. The valve's direct-acting mechanism provides reliable performance in contaminated environments and offers superior dynamic response compared to pilot-operated models. The PRHBCBN is compatible with accumulator circuits due to its lack of pilot control flow, which results in reduced secondary circuit leakage. However, it may not be ideal for counterbalancing applications as it exhibits a transitional step between reducing and relieving modes. The valve allows full reverse flow from reduced pressure port 1 to inlet port 2 but may require an additional check valve if reverse free flow is necessary in the circuit. This model is interchangeable with other three-port reducing and reducing/relieving cartridges of the same frame size, allowing flexibility in mounting configurations.

Direct-acting, pressure reducing/relieving valves reduce a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full-flow relief function from port 1 to tank (port 3). These valves incorporate a damped construction for stable operation allowing the use of high reduced pressure.

  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
  • Leakage specified in Technical Data is out of port 3 with a supply pressure of 2000 psi (140 bar) and the valve set at mid range. This leakage is directly proportional to pressure differential and inversely proportional to viscosity expressed in centistokes.
  • Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals.
  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • All spring ranges are tested for correct operation with 5000 psi (350 bar) inlet pressure.
  • Suitable for accumulator circuits since the absence of pilot control flow results in reduced secondary circuit leakage.
  • Direct acting concept provides highly reliable operation in contaminated systems, especially at dead headed conditions.
  • Unlike pilot operated versions, direct acting valves exhibit a transitional step between reducing and relieving modes. This step equals 5% of the high end of the adjustment range, independent of the valve setting. Therefore, these valves may not be suitable for counterbalancing applications.
  • Direct operated version offers superior dynamic response compared to equivalent pilot operated models.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-17A
Series3
Capacity40 gpm160 L/min.
Factory Pressure Settings Established atblocked control port (dead headed)blocked control port (dead headed)
Maximum Operating Pressure5000 psi350 bar
Maximum Valve Leakage at 110 SUS (24 cSt)4 in³/min.65 cc/min.
Adjustment - Number of Clockwise Turns to Increase Setting55
Valve Hex Size1 1/4 in.31,8 mm
Valve Installation Torque150 - 160 lbf ft203 - 217 Nm
Adjustment Screw Internal Hex Size5/32 in.4 mm
Locknut Hex Size9/16 in.15 mm
Locknut Torque80 - 90 lbf in.9 - 10 Nm
Model Weight1.50 lb0,70 kg
Seal kit - CartridgeViton: 990-017-006

Show FAQ

Additional Resources