SUN HYDRAULICS
PRDNXEV912
$277.90 USD
Tags:
- SUN HYDRAULICS
- Material:PRDNXEV912
- Model:PRDN-XEV@912
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PRDNXEV912 (PRDNXEV912) is an electroproportional, direct-acting reducer-reliever valve designed to efficiently manage hydraulic pressure systems. This valve reduces a high primary pressure at inlet port 2 to a constant reduced pressure at port 1, while providing a full flow relief function from port 1 to tank port 3. It is biased to the reducing mode, with the capability of adjusting the reduced pressure by varying the electrical current to the coil. When the pressure at port 1 exceeds the coil-induced setting, it is relieved to port 3. The valve's transition between reducing and relieving modes is closed, minimizing oil consumption and leakage. For optimal performance, it is recommended that this valve be used with an amplifier featuring current sensing and adjustable dither between 100 - 250 Hz. The maximum operating pressure at port 3 should not exceed 3000 psi (210 bar), as it directly affects the valve setting in a 1:1 ratio. The Sun Hydraulics PRDNXEV912 incorporates floating style construction, reducing the risk of internal parts binding due to installation torque or machining variations. This model features interchangeable coils with other solenoid-operated valves from Sun Hydraulics and can be mounted in either direction on the tube. Its direct-acting design ensures reliable operation even in contaminated systems, making it suitable for accumulator circuits due to minimal secondary circuit leakage without pilot control flow. Additionally, if reverse free flow is needed from reduced pressure port 1 back to inlet port 2, a separate check valve may be required as reverse flow can cause spool closure. The PRDNXEV912 fits into Cavity T-11A Series 1 with a capacity of up to 5 gpm (20 L/min) and can withstand maximum operating pressures of up to 5000 psi (350 bar). It has been engineered for low leakage rates and robust performance in demanding hydraulic applications.
The Sun Hydraulics PRDNXEV912 (PRDNXEV912) is an electroproportional, direct-acting reducer-reliever valve designed to efficiently manage hydraulic pressure systems. This valve reduces a high primary pressure at inlet port 2 to a constant reduced pressure at port 1, while providing a full flow relief function from port 1 to tank port 3. It is biased to the reducing mode, with the capability of adjusting the reduced pressure by varying the electrical current to the coil. When the pressure at port 1 exceeds the coil-induced setting, it is relieved to port 3. The valve's transition between reducing and relieving modes is closed, minimizing oil consumption and leakage. For optimal performance, it is recommended that this valve be used with an amplifier featuring current sensing and adjustable dither between 100 - 250 Hz. The maximum operating pressure at port 3 should not exceed 3000 psi (210 bar), as it directly affects the valve setting in a 1:1 ratio. The Sun Hydraulics PRDNXEV912 incorporates floating style construction, reducing the risk of internal parts binding due to installation torque or machining variations. This model features interchangeable coils with other solenoid-operated valves from Sun Hydraulics and can be mounted in either direction on the tube. Its direct-acting design ensures reliable operation even in contaminated systems, making it suitable for accumulator circuits due to minimal secondary circuit leakage without pilot control flow. Additionally, if reverse free flow is needed from reduced pressure port 1 back to inlet port 2, a separate check valve may be required as reverse flow can cause spool closure. The PRDNXEV912 fits into Cavity T-11A Series 1 with a capacity of up to 5 gpm (20 L/min) and can withstand maximum operating pressures of up to 5000 psi (350 bar). It has been engineered for low leakage rates and robust performance in demanding hydraulic applications.
This electro-proportional, direct-acting reducer/reliever valve reduces a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full flow relief function from port 1 to tank (port 3). The valve is biased to the reducing mode, connecting port 2 to port 1 at a customer specified pressure setting. Increasing the current to the coil will proportionally decrease the reduced pressure at port 1. If pressure at port 1 exceeds the setting induced by the coil, pressure at port 1 is relieved to port 3. This valve is closed in the transition between reducing and relieving resulting in very low consumption of oil.
- Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
- Leakage specified in Technical Data is out of port 3 with a supply pressure of 2000 psi (140 bar) and the valve set at mid range. This leakage is directly proportional to pressure differential and inversely proportional to viscosity expressed in centistokes.
- The transition from reducing to relieving is closed. The result is very low leakage. However, there is a transitional step increase in pressure between reducing and relieving modes. This step equals about 5% of the high end of the adjustment range, independent of the valve setting.
- For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
- Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
- With no electrical signal, the reduced pressure setting will default to the customer specified value. Increasing the command to the coil will proportionally reduce the secondary pressure value.
- Suitable for accumulator circuits since the absence of pilot control flow results in reduced secondary circuit leakage.
- Direct acting concept provides highly reliable operation in contaminated systems, especially at dead headed conditions.
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-11A |
| Series | 1 |
| Capacity | 5 gpm20 L/min. |
| Maximum Operating Pressure | 5000 psi350 bar |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 2.5 in³/min.41 cc/min. |
| Solenoid Tube Diameter | .75 in.19 mm |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Model Weight (with coil) | 1.20 lb0,55 kg |
| Seal kit - Cartridge | Viton: 990-511-006 |
| Seal and nut kit - Coil | Viton: 990-770-006Viton: 990-770-006 |
Show FAQ
Additional Resources
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Expands Corrosion-Resistant Solutions
- Sun Cartridges with EPDM Seals
- Weatherized Solenoid Valves for Harsh Environments
- Configure Your Bluetooth Embedded Amplifier with AmpSet Blue™
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Electro-Proportional Basics Explained
- Proportional Amplifiers and Ancillary Products
- Manufacturing Sun Cartridge Cavities
- Solenoid Coils for Switching and Proportional Valves
- Reducing and Reducing/Relieving Valves
- Electro-Proportional Cartridge Valves
- Electro-Proportional Terms and Definitions
- Cavity Information (S-171) and Tooling
- Sun's Floating Style Screw-In Cartridge
- Fluid and Temperature Recommendations
- Sun Model Code Explanation; 999-901-334
- Performance Data
- Cartridges: Materials of Construction
- Units of Measure, Settings, and Conversions