SUN HYDRAULICS
PRDMXSV212N
$283.60 USD
Tags:
- SUN HYDRAULICS
- Material:PRDMXSV212N
- Model:PRDM-XSV@212N
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PRDMXSV212N (Material Number: PRDMXSV212N) is an electroproportional, direct-acting reducer-reliever valve designed to efficiently manage hydraulic pressure within a system. This valve reduces high primary pressure at inlet port 2 to maintain a consistent reduced pressure at port 1, while offering full flow relief from port 1 to tank port 3. It is engineered with a bias towards reducing mode, where it connects port 2 to port 1 at a specified pressure setting. By increasing the current to the coil, users can proportionally decrease the reduced pressure at port 1. Should the pressure at port 1 exceed the coil's setting, it is relieved to port 3. The valve remains open during transitions from reducing to relieving modes, ensuring excellent pressure control and dynamic response. The PRDMXSV212N supports pressures up to 3000 psi (210 bar) at port 3 and operates reliably even in contaminated systems due to its direct acting concept. It features a slightly open transition from reducing to relieving mode for optimal performance with minimal oil consumption of about 0.1 gpm (0.4 L/min). An amplifier with current sensing and adjustable dither between 100-250 Hz is recommended for best results. The interchangeable coils can be mounted in either direction on the tube. This model ensures that without an electrical signal, the reduced pressure defaults to a customer-specified value; increasing coil command decreases secondary pressure proportionally. For circuits requiring reverse flow from reduced pressure port 1 back to inlet port 2, adding a separate check valve is advisable as full reverse flow may close the main spool. The valve's floating style construction minimizes risks of internal binding due to installation torque or machining variations, making it highly reliable in various applications where precise hydraulic control is crucial.
The Sun Hydraulics PRDMXSV212N (Material Number: PRDMXSV212N) is an electroproportional, direct-acting reducer-reliever valve designed to efficiently manage hydraulic pressure within a system. This valve reduces high primary pressure at inlet port 2 to maintain a consistent reduced pressure at port 1, while offering full flow relief from port 1 to tank port 3. It is engineered with a bias towards reducing mode, where it connects port 2 to port 1 at a specified pressure setting. By increasing the current to the coil, users can proportionally decrease the reduced pressure at port 1. Should the pressure at port 1 exceed the coil's setting, it is relieved to port 3. The valve remains open during transitions from reducing to relieving modes, ensuring excellent pressure control and dynamic response. The PRDMXSV212N supports pressures up to 3000 psi (210 bar) at port 3 and operates reliably even in contaminated systems due to its direct acting concept. It features a slightly open transition from reducing to relieving mode for optimal performance with minimal oil consumption of about 0.1 gpm (0.4 L/min). An amplifier with current sensing and adjustable dither between 100-250 Hz is recommended for best results. The interchangeable coils can be mounted in either direction on the tube. This model ensures that without an electrical signal, the reduced pressure defaults to a customer-specified value; increasing coil command decreases secondary pressure proportionally. For circuits requiring reverse flow from reduced pressure port 1 back to inlet port 2, adding a separate check valve is advisable as full reverse flow may close the main spool. The valve's floating style construction minimizes risks of internal binding due to installation torque or machining variations, making it highly reliable in various applications where precise hydraulic control is crucial.
This electro-proportional, direct-acting reducer/reliever valve reduces a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full flow relief function from port 1 to tank (port 3). The valve is biased to the reducing mode, connecting port 2 to port 1 at a customer specified pressure setting. Increasing the current to the coil will proportionally decrease the reduced pressure at port 1. If pressure at port 1 exceeds the setting induced by the coil, pressure at port 1 is relieved to port 3. This valve is open in the transition from reducing to relieving. It provides good pressure control and dynamic response.
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
- Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
- Direct acting concept provides highly reliable operation in contaminated systems, especially at dead headed conditions.
- The transition from reducing to relieving is slightly open. The result is very good pressure control with oil consumption of about 0.1 gpm (0,4 L/min.).
- For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
- Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
- With no electrical signal, the reduced pressure setting will default to the customer specified value. Increasing the command to the coil will proportionally reduce the secondary pressure value.
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-11A |
| Series | 1 |
| Capacity | 5 gpm20 L/min. |
| Maximum Operating Pressure | 5000 psi350 bar |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 20 in³/min.330 cc/min. |
| Solenoid Tube Diameter | .75 in.19 mm |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Model Weight (with coil) | 1.20 lb0,55 kg |
| Seal kit - Cartridge | Viton: 990-511-006 |
| Seal and nut kit - Coil | Viton: 990-770-006Viton: 990-770-006 |
Show FAQ
Additional Resources
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Expands Corrosion-Resistant Solutions
- Sun Cartridges with EPDM Seals
- Weatherized Solenoid Valves for Harsh Environments
- Configure Your Bluetooth Embedded Amplifier with AmpSet Blue™
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Electro-Proportional Basics Explained
- Proportional Amplifiers and Ancillary Products
- Manufacturing Sun Cartridge Cavities
- Solenoid Coils for Switching and Proportional Valves
- Reducing and Reducing/Relieving Valves
- Electro-Proportional Cartridge Valves
- Electro-Proportional Terms and Definitions
- Cavity Information (S-171) and Tooling
- Sun's Floating Style Screw-In Cartridge
- Fluid and Temperature Recommendations
- Sun Model Code Explanation; 999-901-334
- Performance Data
- Cartridges: Materials of Construction
- Units of Measure, Settings, and Conversions