SUN HYDRAULICS
PRDMXSN712N
$278.30 USD
Tags:
- SUN HYDRAULICS
- Material:PRDMXSN712N
- Model:PRDM-XSN@712N
- Summary:Cartridge
Quantity in stock: 0
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PRDMXSN712N (PRDMXSN712N) is an electroproportional, direct-acting reducer-reliever valve designed for precise pressure control in hydraulic systems. This valve effectively reduces a high primary pressure at the inlet port 2 to a constant reduced pressure at port 1 and includes a full flow relief function from port 1 to tank port 3. It operates by connecting port 2 to port 1 at a customer-specified pressure setting and adjusts the reduced pressure proportionally through increased current to the coil. Should the pressure at port 1 exceed the coil-induced setting, it is relieved to port 3. The valve features an open transition from reducing to relieving, ensuring excellent pressure control with minimal oil consumption of about 0.1 gpm (0.4 L/min). Designed for reliability in contaminated systems, especially under dead-headed conditions, it incorporates Sun's floating style construction to prevent internal binding due to excessive torque or machining variations. The valve supports pressures up to 3000 psi (210 bar) at port 3, which directly adds to the valve setting in a 1:1 ratio. For optimal performance, using an amplifier with adjustable dither between 100 - 250 Hz is recommended. Coils are interchangeable with Sun's other solenoid-operated valves and can be mounted bidirectionally on the tube. In instances requiring reverse flow from reduced pressure port 1 back to inlet port 2, consider adding a separate check valve as reverse flow may cause the main spool to close. The PRDMXSN712N is compatible with all three-port reducing and reducing-relieving cartridges of similar frame size for easy interchangeability within hydraulic circuits.
The Sun Hydraulics PRDMXSN712N (PRDMXSN712N) is an electroproportional, direct-acting reducer-reliever valve designed for precise pressure control in hydraulic systems. This valve effectively reduces a high primary pressure at the inlet port 2 to a constant reduced pressure at port 1 and includes a full flow relief function from port 1 to tank port 3. It operates by connecting port 2 to port 1 at a customer-specified pressure setting and adjusts the reduced pressure proportionally through increased current to the coil. Should the pressure at port 1 exceed the coil-induced setting, it is relieved to port 3. The valve features an open transition from reducing to relieving, ensuring excellent pressure control with minimal oil consumption of about 0.1 gpm (0.4 L/min). Designed for reliability in contaminated systems, especially under dead-headed conditions, it incorporates Sun's floating style construction to prevent internal binding due to excessive torque or machining variations. The valve supports pressures up to 3000 psi (210 bar) at port 3, which directly adds to the valve setting in a 1:1 ratio. For optimal performance, using an amplifier with adjustable dither between 100 - 250 Hz is recommended. Coils are interchangeable with Sun's other solenoid-operated valves and can be mounted bidirectionally on the tube. In instances requiring reverse flow from reduced pressure port 1 back to inlet port 2, consider adding a separate check valve as reverse flow may cause the main spool to close. The PRDMXSN712N is compatible with all three-port reducing and reducing-relieving cartridges of similar frame size for easy interchangeability within hydraulic circuits.
This electro-proportional, direct-acting reducer/reliever valve reduces a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full flow relief function from port 1 to tank (port 3). The valve is biased to the reducing mode, connecting port 2 to port 1 at a customer specified pressure setting. Increasing the current to the coil will proportionally decrease the reduced pressure at port 1. If pressure at port 1 exceeds the setting induced by the coil, pressure at port 1 is relieved to port 3. This valve is open in the transition from reducing to relieving. It provides good pressure control and dynamic response.
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
- Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
- Direct acting concept provides highly reliable operation in contaminated systems, especially at dead headed conditions.
- The transition from reducing to relieving is slightly open. The result is very good pressure control with oil consumption of about 0.1 gpm (0,4 L/min.).
- For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
- Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
- With no electrical signal, the reduced pressure setting will default to the customer specified value. Increasing the command to the coil will proportionally reduce the secondary pressure value.
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-11A |
| Series | 1 |
| Capacity | 5 gpm20 L/min. |
| Maximum Operating Pressure | 5000 psi350 bar |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 20 in³/min.330 cc/min. |
| Solenoid Tube Diameter | .75 in.19 mm |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Model Weight (with coil) | 1.20 lb0,55 kg |
| Seal kit - Cartridge | Viton: 990-511-006 |
| Seal and nut kit - Coil | Viton: 990-770-006Viton: 990-770-006 |
Show FAQ
Additional Resources
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Expands Corrosion-Resistant Solutions
- Sun Cartridges with EPDM Seals
- Weatherized Solenoid Valves for Harsh Environments
- Configure Your Bluetooth Embedded Amplifier with AmpSet Blue™
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Electro-Proportional Basics Explained
- Proportional Amplifiers and Ancillary Products
- Manufacturing Sun Cartridge Cavities
- Solenoid Coils for Switching and Proportional Valves
- Reducing and Reducing/Relieving Valves
- Electro-Proportional Cartridge Valves
- Electro-Proportional Terms and Definitions
- Cavity Information (S-171) and Tooling
- Sun's Floating Style Screw-In Cartridge
- Fluid and Temperature Recommendations
- Sun Model Code Explanation; 999-901-334
- Performance Data
- Cartridges: Materials of Construction
- Units of Measure, Settings, and Conversions