You are using an outdated browser. For a faster, safer browsing experience, upgrade for free today.

SUN HYDRAULICS
PRDMXSN71299


$294.80 USD

Tags:

  • SUN HYDRAULICS
  • Material:PRDMXSN71299
  • Model:PRDM-XSN@71299
  • Summary:Cartridge

Quantity in stock: 0

Note: Sales tax, and shipping will be calculated at checkout.
***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PRDMXSN71299 (PRDMXSN71299) is an electroproportional, direct-acting reducer-reliever valve designed to efficiently manage hydraulic pressure by reducing a high primary pressure at inlet port 2 to a consistent reduced pressure at port 1, while also providing a full flow relief function from port 1 to tank port 3. This valve is optimized for applications requiring precise pressure control and dynamic response, as it is biased towards the reducing mode, connecting port 2 to port 1 at a specified customer pressure setting. The current supplied to the coil proportionally decreases the reduced pressure at port 1. If the pressure at port 1 exceeds the coil-induced setting, it is relieved to port 3. The valve's open transition from reducing to relieving ensures reliable operation in contaminated systems and dead-headed conditions. For optimal performance, it's recommended to use an amplifier with current sensing and adjustable dither between 100-250 Hz. The valve's construction allows for coil interchangeability with other solenoid-operated valves from Sun Hydraulics, offering flexibility in installation direction on the tube. It features a direct acting concept that supports highly reliable operation under various conditions, and its floating style construction minimizes internal part binding due to installation torque or machining variations. With a capacity of up to 5 gpm (20 L/min) and maximum operating pressure of 5000 psi (350 bar), this valve is suitable for demanding hydraulic systems requiring precise control and reliability.

This electro-proportional, direct-acting reducer/reliever valve reduces a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full flow relief function from port 1 to tank (port 3). The valve is biased to the reducing mode, connecting port 2 to port 1 at a customer specified pressure setting. Increasing the current to the coil will proportionally decrease the reduced pressure at port 1. If pressure at port 1 exceeds the setting induced by the coil, pressure at port 1 is relieved to port 3. This valve is open in the transition from reducing to relieving. It provides good pressure control and dynamic response.

  • Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
  • Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
  • Direct acting concept provides highly reliable operation in contaminated systems, especially at dead headed conditions.
  • The transition from reducing to relieving is slightly open. The result is very good pressure control with oil consumption of about 0.1 gpm (0,4 L/min.).
  • For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
  • Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
  • With no electrical signal, the reduced pressure setting will default to the customer specified value. Increasing the command to the coil will proportionally reduce the secondary pressure value.
  • Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
  • All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
  • Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.

CavityT-11A
Series1
Capacity5 gpm20 L/min.
Maximum Operating Pressure5000 psi350 bar
Maximum Valve Leakage at 110 SUS (24 cSt)20 in³/min.330 cc/min.
Solenoid Tube Diameter.75 in.19 mm
Valve Hex Size7/8 in.22,2 mm
Valve Installation Torque30 - 35 lbf ft41 - 47 Nm
Model Weight (with coil)1.20 lb0,55 kg
Seal kit - CartridgeViton: 990-511-006
Seal and nut kit - CoilViton: 990-770-006Viton: 990-770-006

Show FAQ

Additional Resources