***Disclaimer: The following summary contains information gathered from various sources such as product descriptions, technical specifications and catalogs. While efforts have been made to provide accurate details, inaccuracies may occur. It is advised to verify all information by contacting Sun Hydraulics directly.***
The Sun Hydraulics PRDMXSN2B12A (PRDMXSN2B12A) is an electroproportional, direct-acting reducer-reliever valve designed to manage high primary pressures by reducing them to a constant level at the outlet port, with an integrated relief function. This valve operates by connecting the inlet port to the outlet port at a customer-specified pressure setting, and increasing the current to the coil will proportionally decrease this reduced pressure. If the pressure at the outlet exceeds the coil-induced setting, it is relieved to a tank port. The valve's design ensures good pressure control and dynamic response, with an important feature being its slightly open transition from reducing to relieving mode. This product is particularly reliable in contaminated systems due to its direct-acting concept, which makes it suitable for dead-headed conditions. For optimal performance, it is recommended to use an amplifier with current sensing and adjustable dither between 100-250 Hz. The valve's coils are interchangeable with other solenoid-operated valves from Sun Hydraulics and can be mounted in either direction on the tube. The PRDMXSN2B12A has a maximum operating pressure of 5000 psi (350 bar) and features Sun's floating style construction to minimize internal part binding due to excessive installation torque or machining variations. It incorporates a three-port configuration that allows physical interchangeability with other reducing-relieving cartridges of the same frame size. The valve's flow capacity is rated at 5 gpm (20 L/min), and for applications requiring reverse flow from reduced pressure port 1 to inlet port 2, an additional check valve may be necessary in the circuit.
The Sun Hydraulics PRDMXSN2B12A (PRDMXSN2B12A) is an electroproportional, direct-acting reducer-reliever valve designed to manage high primary pressures by reducing them to a constant level at the outlet port, with an integrated relief function. This valve operates by connecting the inlet port to the outlet port at a customer-specified pressure setting, and increasing the current to the coil will proportionally decrease this reduced pressure. If the pressure at the outlet exceeds the coil-induced setting, it is relieved to a tank port. The valve's design ensures good pressure control and dynamic response, with an important feature being its slightly open transition from reducing to relieving mode. This product is particularly reliable in contaminated systems due to its direct-acting concept, which makes it suitable for dead-headed conditions. For optimal performance, it is recommended to use an amplifier with current sensing and adjustable dither between 100-250 Hz. The valve's coils are interchangeable with other solenoid-operated valves from Sun Hydraulics and can be mounted in either direction on the tube. The PRDMXSN2B12A has a maximum operating pressure of 5000 psi (350 bar) and features Sun's floating style construction to minimize internal part binding due to excessive installation torque or machining variations. It incorporates a three-port configuration that allows physical interchangeability with other reducing-relieving cartridges of the same frame size. The valve's flow capacity is rated at 5 gpm (20 L/min), and for applications requiring reverse flow from reduced pressure port 1 to inlet port 2, an additional check valve may be necessary in the circuit.
This electro-proportional, direct-acting reducer/reliever valve reduces a high primary pressure at the inlet (port 2) to a constant reduced pressure at port 1, with a full flow relief function from port 1 to tank (port 3). The valve is biased to the reducing mode, connecting port 2 to port 1 at a customer specified pressure setting. Increasing the current to the coil will proportionally decrease the reduced pressure at port 1. If pressure at port 1 exceeds the setting induced by the coil, pressure at port 1 is relieved to port 3. This valve is open in the transition from reducing to relieving. It provides good pressure control and dynamic response.
- Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 3000 psi (210 bar).
- Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
- Direct acting concept provides highly reliable operation in contaminated systems, especially at dead headed conditions.
- The transition from reducing to relieving is slightly open. The result is very good pressure control with oil consumption of about 0.1 gpm (0,4 L/min.).
- For optimum performance, an amplifier with current sensing and adjustable dither should be used. Dither should be adjustable between 100 - 250 Hz.
- Coils are interchangeable with Sun's other full flow, solenoid-operated valves and can be mounted on the tube in either direction.
- With no electrical signal, the reduced pressure setting will default to the customer specified value. Increasing the command to the coil will proportionally reduce the secondary pressure value.
- Full reverse flow from reduced pressure (port 1) to inlet (port 2) may cause the main spool to close. If reverse free flow is required in the circuit, consider adding a separate check valve to the circuit.
- All three-port pressure reducing and reducing/relieving cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). When considering mounting configurations, it is sometimes recommended that a full capacity return line (port 3) be used with reducing/relieving cartridges.
- Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
| Cavity | T-11A |
| Series | 1 |
| Capacity | 5 gpm20 L/min. |
| Maximum Operating Pressure | 5000 psi350 bar |
| Maximum Valve Leakage at 110 SUS (24 cSt) | 20 in³/min.330 cc/min. |
| Solenoid Tube Diameter | .75 in.19 mm |
| Valve Hex Size | 7/8 in.22,2 mm |
| Valve Installation Torque | 30 - 35 lbf ft41 - 47 Nm |
| Model Weight (with coil) | 1.20 lb0,55 kg |
| Seal kit - Cartridge | Viton: 990-511-006 |
| Seal and nut kit - Coil | Viton: 990-770-006Viton: 990-770-006 |
Show FAQ
Additional Resources
- Sun Offers Zinc-Nickel Plating for Corrosion Resistance
- Sun Expands Corrosion-Resistant Solutions
- Sun Cartridges with EPDM Seals
- Weatherized Solenoid Valves for Harsh Environments
- Configure Your Bluetooth Embedded Amplifier with AmpSet Blue™
- Series 4 PLUS Cartridges Offer Higher Flows with Lower Pressure Losses
- QuickDesign with SmartConnect Offers Drag-and-Drop Schematic Tool
- Electro-Proportional Basics Explained
- Proportional Amplifiers and Ancillary Products
- Manufacturing Sun Cartridge Cavities
- Solenoid Coils for Switching and Proportional Valves
- Reducing and Reducing/Relieving Valves
- Electro-Proportional Cartridge Valves
- Electro-Proportional Terms and Definitions
- Cavity Information (S-171) and Tooling
- Sun's Floating Style Screw-In Cartridge
- Fluid and Temperature Recommendations
- Sun Model Code Explanation; 999-901-334
- Performance Data
- Cartridges: Materials of Construction
- Units of Measure, Settings, and Conversions